User`s manual
Table Of Contents
- Preliminary remarks
- Introduction
- New functions
- Installation
- Best practice
- Requirements
- Used ports
- Setup
- Upgrade from Apollo 1.3 to Apollo 1.4
- Upgrade from Apollo 1.4 to Apollo 1.4SR1
- Upgrading from Apollo 1.4 to Apollo 1.5
- Upgrading from Apollo 1.5 to Apollo 1.6
- Upgrading from Apollo 1.6 to Apollo 1.7
- Upgrading from Apollo 1.7 to Apollo 1.8
- Upgrading from Apollo 1.8 to Apollo 1.9
- Upgrading the Display Wall configuration
- Control Room Configurator
- Viewer
- Concept
- Apollo 1.9 Viewers
- Limitations
- Memory requirements (minimal RAM size)
- Communication memory
- Requirements
- Steps required to configure the FRG Viewer
- Steps required to configure the Visu Viewer
- Steps required to configure the Cottus Viewer
- Steps required to configure the VNC Viewer
- Steps required to configure the ProViewer
- Steps required to configure the Web Viewer
- Steps required to configure the MPEG Viewer
- Steps required to configure the VTplus Viewer
- Launching Viewer
- Controlling Viewers
- VNC Viewer
- Explorer
- Starting the Explorer
- Explorer User Interface
- Object Tree
- Source Tree View
- Explorer workspace
- Explorer menu bar
- Help menu
- Remote Desktop menu
- Layout Selector menu
- Explorer tool bar
- Device Manager in the Explorer
- Explorer Context Menu
- Drag&Drop functionality
- Layout Editor
- Desktop Server
- Project Backup
- Command Interface
- Device command Interface
- Desktop command Interface
- Viewer command Interface
- Apollo Explorer command interface
- Apollo Layout Editor command interface
- Apollo Layout Selector command interface
- Apollo Remote Desktop command interface
- Apollo Database Convertor command interface
- Apollo Window Detector command interface
- Control Room Bus services
- Control Room Bus
- Serial command interface
- TCPIP command interface
- Application management
- License management
- Time synchronization
- Log file
- Security Provider
- Defining accessGroups
- Configuration of restricted objects
- Permissions
- Restrictions for regions
- Restrictions for layouts
- Restrictions for shortcuts
- Restrictions for advanced menus
- Window Properties|Description
- Window Properties|Sizable
- Window Properties|Always on Top
- Window Properties|Visible
- Edit|Invisible Windows
- Edit|Keyboardinput
- Edit|CommandLine
- Edit|Permissions
- Edit|SaveLayout
- Customized configuration and uninstallation of Apollo
- Soap API Service
- Appendix
- Hotline
5. Control Room Configurator
56/402
__________________________________________________
Barco – Apollo – DOC-3197-2 – user's manual – Revision 08 – November 2006
5.3.2.35 Host IF Card (Host interface card)
Data Connection
Point (blue):
PCI_Bus PCI board for Transform A
Possible to connect with TransForm A OmniBus A18
and TransForm A OmniBus A12
5.3.2.36 IO card (serial I/O card)
Serial Interface
(rot):
Serial_Output COM3
Serial_Output COM4
Baudrate can be set
to
1200/2400/9600/1
9200/38400
PCI Card for Eos
Includes two additional serial interfaces, e.g. for
connecting a Visu
Number of COM ports depends on the reserved COM
ports on Eos or Argus
5.3.2.37 I/O card Parallel Port
Parallel Interface
(rot):
Parallel_Output PCI Card for TransForm A
Includes an additional parallel interface.
5.3.2.38 Data field
This field can not be edited, but displays the information of the file and the file properties entered in the file
properties dialog.
Refer to the following table to learn about the relationship
Data field File | Properties
Copyright Company
Project Category
Document Context Topic
Title Title
Starting with Control Room Configurator 1.4.4, the version of the Control Room
Configurator is indicated in the version field.
Please note: the version is only updated when the drawing is saved, exported or printed!