User`s manual

Table Of Contents
6. Viewer
Barco – Apollo – DOC-3197-2 – user's manual – Revision 08 – November 2006
__________________________________________________
71/402
6.6.2 Steps required to configure the Visu Viewer
Visu is a device to display video and RGB sources and is addressed by the Barco RC Agent as such.
The tree view of the Apollo Explorer also lists this as a device and it has to be an entry in the RC Agent as well.
Follow these steps to adjust the Visu hardware for Apollo:
Copy the Visu firmware files (located on the Control Room Suite CD-ROM in the folder RCAgent\RCAgent
1.4.4) to the directory of the Barco RC Agent on the workstation (default path during the installation of the
Barco RC Agent is C:\Program Files\Barco RC Agent).
Configure the Visu
VisuVisu
Visu in the Visio file of the ApolloProject and create the required configuration files using the
Export
ExportExport
Export command. Configuration is done either by specifying the correct position of the resolution switch on
the graphic card (recommended) or manually by setting the respective Visu parameters of the Visu shape.
switch projection module resolution DDC active
0 OVERVIEW-ML VGA 640×480 no
1 OVERVIEW-ML, OVERVIEW-MD
OVERVIEW-ME
SVGA 800×600 no
2 OVERVIEW-ML XGA 1024×768 no
4 OVERVIEW-MP, ATLAS67C4 XGA 1024×768 no
5 OVERVIEW-MP; ATLAS67C4
OVERVIEW-ME
SVGA 800×600 no
6 digital output, 60 Hz VESA timing SXGA 1280×1024 no
F digital output with DDC
connected display device provides
DDC information
VGA 640×480
SVGA 800×600
XGA 1024×768
SXGA 1280×1024
UXGA 1600×1200
yes
analog output (CRT) software defined no
Copy the files to the ApolloProject
ApolloProject ApolloProject
ApolloProject directory.
Launch the Apollo Explorer.
..
.
The Device branch has to list the Visu.
Click on the name in the main Explorer
ExplorerExplorer
Explorer window (right mouse button). The Device Manager opens the dialog
box for setting the Visu parameters. Check the Status entry on the General
tab. The device has to be ready
for operation.
If necessary, adjust the settings on the dialogs of the Device Manager. Write down the new values, since
the Visu Basic Configuration file has to be adjusted accordingly.
Open the Visio configuration file, select the Visu shape, and enter the new values of the parameters.
Export the configuration, and copy the files to the ApolloProject directory.
Do not modify any of the parameters in the VisuBasicConfiguration.ini!