User`s manual
Table Of Contents
- Preliminary remarks
- Introduction
- New functions
- Installation
- Best practice
- Requirements
- Used ports
- Setup
- Upgrade from Apollo 1.3 to Apollo 1.4
- Upgrade from Apollo 1.4 to Apollo 1.4SR1
- Upgrading from Apollo 1.4 to Apollo 1.5
- Upgrading from Apollo 1.5 to Apollo 1.6
- Upgrading from Apollo 1.6 to Apollo 1.7
- Upgrading from Apollo 1.7 to Apollo 1.8
- Upgrading from Apollo 1.8 to Apollo 1.9
- Upgrading the Display Wall configuration
- Control Room Configurator
- Viewer
- Concept
- Apollo 1.9 Viewers
- Limitations
- Memory requirements (minimal RAM size)
- Communication memory
- Requirements
- Steps required to configure the FRG Viewer
- Steps required to configure the Visu Viewer
- Steps required to configure the Cottus Viewer
- Steps required to configure the VNC Viewer
- Steps required to configure the ProViewer
- Steps required to configure the Web Viewer
- Steps required to configure the MPEG Viewer
- Steps required to configure the VTplus Viewer
- Launching Viewer
- Controlling Viewers
- VNC Viewer
- Explorer
- Starting the Explorer
- Explorer User Interface
- Object Tree
- Source Tree View
- Explorer workspace
- Explorer menu bar
- Help menu
- Remote Desktop menu
- Layout Selector menu
- Explorer tool bar
- Device Manager in the Explorer
- Explorer Context Menu
- Drag&Drop functionality
- Layout Editor
- Desktop Server
- Project Backup
- Command Interface
- Device command Interface
- Desktop command Interface
- Viewer command Interface
- Apollo Explorer command interface
- Apollo Layout Editor command interface
- Apollo Layout Selector command interface
- Apollo Remote Desktop command interface
- Apollo Database Convertor command interface
- Apollo Window Detector command interface
- Control Room Bus services
- Control Room Bus
- Serial command interface
- TCPIP command interface
- Application management
- License management
- Time synchronization
- Log file
- Security Provider
- Defining accessGroups
- Configuration of restricted objects
- Permissions
- Restrictions for regions
- Restrictions for layouts
- Restrictions for shortcuts
- Restrictions for advanced menus
- Window Properties|Description
- Window Properties|Sizable
- Window Properties|Always on Top
- Window Properties|Visible
- Edit|Invisible Windows
- Edit|Keyboardinput
- Edit|CommandLine
- Edit|Permissions
- Edit|SaveLayout
- Customized configuration and uninstallation of Apollo
- Soap API Service
- Appendix
- Hotline

6. Viewer
Barco – Apollo – DOC-3197-2 – user's manual – Revision 08 – November 2006
__________________________________________________
71/402
6.6.2 Steps required to configure the Visu Viewer
Visu is a device to display video and RGB sources and is addressed by the Barco RC Agent as such.
The tree view of the Apollo Explorer also lists this as a device and it has to be an entry in the RC Agent as well.
Follow these steps to adjust the Visu hardware for Apollo:
• Copy the Visu firmware files (located on the Control Room Suite CD-ROM in the folder RCAgent\RCAgent
1.4.4) to the directory of the Barco RC Agent on the workstation (default path during the installation of the
Barco RC Agent is C:\Program Files\Barco RC Agent).
• Configure the Visu
VisuVisu
Visu in the Visio file of the ApolloProject and create the required configuration files using the
Export
ExportExport
Export command. Configuration is done either by specifying the correct position of the resolution switch on
the graphic card (recommended) or manually by setting the respective Visu parameters of the Visu shape.
switch projection module resolution DDC active
0 OVERVIEW-ML VGA 640×480 no
1 OVERVIEW-ML, OVERVIEW-MD
OVERVIEW-ME
SVGA 800×600 no
2 OVERVIEW-ML XGA 1024×768 no
4 OVERVIEW-MP, ATLAS67C4 XGA 1024×768 no
5 OVERVIEW-MP; ATLAS67C4
OVERVIEW-ME
SVGA 800×600 no
6 digital output, 60 Hz VESA timing SXGA 1280×1024 no
F digital output with DDC
connected display device provides
DDC information
VGA 640×480
SVGA 800×600
XGA 1024×768
SXGA 1280×1024
UXGA 1600×1200
yes
analog output (CRT) software defined no
• Copy the files to the ApolloProject
ApolloProject ApolloProject
ApolloProject directory.
• Launch the Apollo Explorer.
..
.
• The Device branch has to list the Visu.
• Click on the name in the main Explorer
ExplorerExplorer
Explorer window (right mouse button). The Device Manager opens the dialog
box for setting the Visu parameters. Check the Status entry on the General
tab. The device has to be ready
for operation.
• If necessary, adjust the settings on the dialogs of the Device Manager. Write down the new values, since
the Visu Basic Configuration file has to be adjusted accordingly.
• Open the Visio configuration file, select the Visu shape, and enter the new values of the parameters.
• Export the configuration, and copy the files to the ApolloProject directory.
Do not modify any of the parameters in the VisuBasicConfiguration.ini!