6.6.5 Steps required to configure the ProViewer
The ProServer has to be installed on every host workstation with a screen to be displayed on the Display Wall.
Select ProServer when installing Apollo, cf. Setup.
The best color depth for the ProServer wrt performance is 32Bit. However depending on the desktop resolution,
it might be mandatory to set the color depth to 16Bit: there is a limitation of max. 120 Mbyte display memory!
In case the max. display memory is exceeded, the error in the ProServer log file reads:
"Failed to create memory bit map: error = 8
To resolve this problem, reduce the color depth of the desktop!
Log into the host workstation with administrative privileges.
Place the CD into the CD drive and run setup.exe
setup.exesetup.exe
setup.exe. The Install Shield Wizard will guide you through the installa-
tion process. Select Custom, and then ProServer. Follow the displayed instructions.
After the installation of the ProServer, it has to be configured. If it is unconfigured, the following warning pops
up:
After accepting, the configuration dialog is displayed:
It is highly recommended to enter a password and NOT to remove the check mark in the
Disable empty password box.