Installation Guide

Conbraco Industries, Inc.
Matthews, NC 28105
1.888.229.2874
www.apolloflow.com
is-69PTBJ0010C_04/06/17
INSTRUCTION SHEET
PEX One Hand Pinch Clamp Fastening Tool
Calibration
PEX
Apollo PEX tools are pre-calibrated for up to 10,000 uses. After repeated use of this tool, it
may require calibration. A calibration tool is provided with the fastening tool.
1. Ratchet the Pinch Tool to the
closed position until the LED
light comes on.
3. To adjust the jaw gap, locate the
hex screw hole inside the tool. (No
need to take apart the tool to
access the calibration hole.)
Insert the enclosed Allen wrench
into the hole. Turning the wrench
counter-clockwise will cause the
gap to increase. Turning the
wrench clockwise will cause the
jaw gap to decrease.
2. Use the Calibration Tool to gauge
the jaw gap. The jaw gap should
be between 1.2 mm and 1.4 mm.
If the 1.4 mm side of the gauge
slides into the gap, then the jaw
space is too large. If the 1.2 mm
side of the gauge cannot slide
into the gap, then the jaw space
is too narrow.
Hex Screw
Hole
Allen wrench
inside hole
How to change the LED light batteries:
1. Locate the
LED light battery
compartment.
Battery
Compartment
2. The battery
compartment
has a plastic
cover attached
with two screws.
3. Remove the
screws and
cover.
4. Remove the old
batteries.
5. Place the new
batteries with the
positive side
facing up.
Replace the
cover and tighten
the screws.
69PTBJ0010C