Specifications
Gaia
GAIA.ASU.SP.ESM.00007
Issue 2.00
Page 34 of 79
Astrium Ltd owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in 
whole or in part be reproduced, copied, or communicated to any person without written permission from the owner. 
GAIA.ASU.SP.ESM.00007 (Avionics SCOE Req Iss 2).doc 
3.6.5  Combined CPS Interfaces 
The Gaia Combined CPS subsystem is controlled and monitored by the Spacecraft Electrical Interface Unit 
(EIU) and comprises: 
18 x Latch Valves (LV) operating in (9+9) cold redundancy: (8+8) for the Thruster lines, (1+1) for the Tanks 
18 x Latch Valves status micro-switches operating in (10+10) cold redundancy 
16 x Flow Control Valves operating in (8+8) cold redundancy to control 2 banks of (8+8) 10N Thrusters 
4 x Pressure Transducers for Tank Pressure monitoring 
AVI-311/GSE-SYS-405/T 
The Avionics SCOE shall provide interfaces to the EIU to simulate the presence of the Combined 
CPS subsystem. 
AVI-295/EIU-701,EIU-702/T 
The CPS Interfaces shall comprise the following functions. 
LV Command Pulse Acquisition (18 LV, 1 x OPEN and 1 x CLOSED commands per Latch Valve) 
LV Status Simulation (1 micro-switch simulation per Latch Valve) 
FCV Command Pulse Acquisition (16 FCV) 
4 x Pressure Transducer Simulations 
3.6.5.1 CPS LV Command Pulse Acquisition 
AVI-327/EIU-706/T 
The LV Command Pulse Acquisition interface shall be provided by fixed loads (36x) simulating the 
OPEN and CLOSE coils for each of 18 LV. 
AVI-328/EIU-706/T 
LV Command Acquisition interface shall conform to the following specifications: [AD06] Table 3.5-35 
(Latch Valve Interface Specification - Receiver Circuit Specification). 
AVI-382/GSE-SYS-405/T 
LV Command Pulse Acquisition shall provide Latch Valve state (OPEN/CLOSE) and measurement of 
the Command pulse width, as detailed below: 
Pulse WIDTH resolution 
100.0 µs - for nominal 50-100ms pulse 
Latch Valve STATE  OPEN = acquisition of a 'valid' pulse on the corresponding LV 
OPEN coil 
CLOSED = acquisition of a 'valid' pulse on the corresponding 
LV CLOSE coil 
A 'valid' pulse shall be as defined in [AD06] Table 3.5-35. 
Table 3.6-2: CPS - LV Command Pulse Measurement Specification 
AVI-1886/CREATED/T 
Measurement of LV Command pulses shall be triggered asynchronously by detection of an incoming 
pulse with the following specifications: 
•  Pulse Width > 1ms 
•  Pulse Amplitude > 10.0V 
AVI-389/CREATED/T 
LV STATE (OPEN/CLOSE) shall be made available to the RTS. 
AVI-2768/EIU-3393, GSE-SYS-761/T 
It shall be possible to acquire the LV pulses simultaneously on all channels. 