AFUX Series
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 7CD, 9EFG
AFU Series
NEMA 3, 4, 4X, 12
Controls
CONTROLS: HAZARDOUS LOCATION CONVEYOR SWITCHES
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
484
AFU and AFUX Conveyor Control Switch Wiring Information and Dimensions
Pull Cord Type, Left or Right Hand, Single or Double End.
Wiring Information
Description Diagram
Single Pole Double Throw Circuit
Single Pole, Double Throw Micro Switch Rating
• 20 Amps, 125, 250 or 480 Vac
• 10 Amps, 125 Vac “L” (tungsten lamp load)
• 1 HP, 125 Vac
• 2 HP, 250 Vac
• 1/2 Amp, 125 Vdc
• 1/4 Amp, 250 Vdc
Two Circuit, Double Break Micro Switch Rating
• 15 Amps, 120, 240, 480 or 600 Vac
• 1/2 HP, 120 Vac
• 1 HP, 240 Vac
• 0.8 Amp, 115 Vdc
• 0.4 Amp, 230 Vdc 0.8, 250 Vac
• 1/2 Amp, 125 Vdc
• 1/4 Amp, 250 Vdc
Two circuit double break switches must be wired to equal voltage sources and the same polarity. Loads should be on the same side of the lines.
1B has the same polarity as 3A.
Dimensions
Front Side Mounting Bar