Cut Sheet
Areamaster
™
Generation 2 HL LED Luminaire
Floodlight for Hazardous Locations
Electrical Ratings
Voltage Suffix Voltage (V) Input Power (Watts)
Input Current
(Amps) Power Factor (PF)
Total Harmonic
Distortion (THD) Model Number
BU
120Vac 180 1.52
>.9 <20%
AMLHL1
277Vac 176 0.67
170Vdc 172 1.02
N/A N/A
300Vdc 170 0.57
BH
347Vac 179 0.52
>.9 <20%
480Vac 179 0.39
BU
120Vac 231 1.94
>.9 <20%
AMLHL2
277Vac 231 0.88
170Vdc 220 1.30
N/A N/A
300Vdc 217 0.72
BH
347Vac 219 0.64
>.9 <20%
480Vac 219 0.47
BU
120Vac 317 2.67
>.9 <20%
AMLHL3
277Vac 303 1.15
170Vdc 305 1.80
N/A N/A
300Vdc 298 0.99
BH
347Vac 299 0.87
>.9 <20%
480Vac 298 0.63
Surge Protection: Integral 6KV surge protection. Option for up to 10KV surge protection. (cCSAus only).
All ratings are typical.
Luminaire Category Image
Frontal Projected Area
(FPA) ft
2
Drag Coefficient
(DC)
Effective Projected Area
(EPA) = FPA*DC ft
2
90°toGround-Worst
CaseMounting
2.04 1.20 2.45
45°toGround-Standard
Mounting
1.44 1.20 1.73
Wind Direction
Wind Direction
NEC/CEC:
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2 Group IIC
Class II, Division 1 and 2, Groups E, F, G
Class III
Zone 20 and 21 Group IIIC
NEC/CEC:
Zone 22, Group IIIB
Simultaneous Exposure
Marine Outside Type (Salt Water) for USA ONLY
Wet Locations
Type 3R, 4, 4X, IP66/67
ATEX/IECEx:
Zone 2, 22
IP66
II 3GD
IK10
Ex ec llC T4
LED/FLooDLights: NEC/CEC, AtEx/iECEx ENCLosED AND gAskEtED
Visit our website at www.emerson.com or contact us at (800) 621-1506.
© April 2018
278