Cut Sheet

Photometric Data
Total Luminaire Efficiency = 76.6%
REPORT NUMBER: CJBF32AN
32 W Fluorescent Lamp with Globe and 30° Angle Dome Reflector *
CIE Type - Direct
Plane
Spacing
Criteria
Maximum Candela = 467
Located at Horizontal Angle = 90, Vertical Angle = 40
#1 - Vertical Plane through Horizontal Angles (90-270)
(Through Max. Cd.)
#2 - Horizontal Cone through Vertical Angle (40)
(Through Max. Cd.)
0-180 1.48 Coefficients of Utilization - Zonal Cavity Method
90-270 1.62 Effective Floor Cavity Reflectance 0.20
Diagonal 1.54 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens
0
90 90 90 90 88 88 88 88 83 83 83 79 79 79 75 75 75 73
0-10 42.08
1
81 76 72 69 78 74 71 67 70 67 64 67 64 62 63 61 59 58
10-20 124.46
2
73 65 59 54 70 64 58 53 60 56 52 57 53 50 54 51 48 46
20-30 205.20
3
66 57 50 44 63 55 49 44 52 47 42 50 45 41 47 43 40 38
30-40 273.31
4
60 50 42 37 58 48 42 36 46 40 35 44 39 35 42 37 34 32
40-50 299.53
5
55 44 37 31 53 43 36 31 41 35 30 39 34 30 37 33 29 27
50-60 283.93
6
50 39 32 27 49 39 32 27 37 31 26 35 30 26 34 29 25 23
60-70 240.60
7
47 36 28 23 45 35 28 23 33 27 23 32 26 22 31 26 22 20
70-80 181.91
8
43 32 25 21 42 32 25 21 30 24 20 29 24 20 28 23 20 18
80-90 110.47
9
40 30 23 18 39 29 23 18 28 22 18 27 22 18 26 21 18 16
90-100 50.28
10
38 27 21 17 36 27 21 17 26 20 16 25 20 16 24 19 16 14
100-110 18.05
110-120 5.01 Zonal Lumen Summary
120-130 1.80 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 1.13 0-30 371.75 15.5 20.2 90-120 73.34 3.1 4.0
140-150 0.05 0-40 645.06 26.9 35.1 90-130 75.13 3.1 4.1
150-160 0.00 0-60 1228.52 51.2 66.8 90-150 76.32 3.2 4.1
160-170 0.00 0-90 1761.50 73.4 95.8 90-180 76.32 3.2 4.2
170-180 0.00 0-180 1837.81 76.6 100.0
Total Luminaire Efficiency = 79.8%
REPORT NUMBER: CMBF64G
64 W (two 32 W lamps) Fluorescent Fixture with Globe only **
CIE Type - Semi-Direct
Plane
Spacing
Criteria
Maximum Candela = 493
Located at Horizontal Angle = 0, Vertical Angle = 70
#1 – Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (70)
(Through Max. Cd.)
0-180 2.88 Coefficients of Utilization - Zonal Cavity Method
90-270 2.88 Effective Floor Cavity Reflectance 0.20
Diagonal 2.82 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 90 90 90 90 85 85 85 85 76 76 76 68 68 68 60 60 60 57
0-10 17.70 1 76 70 65 60 71 66 61 57 58 54 51 51 48 45 45 42 40 36
10-20 61.05 2 67 58 51 45 63 55 48 42 48 43 38 42 37 34 36 32 29 26
20-30 132.44 3 60 49 41 35 56 46 39 33 40 34 29 35 30 26 30 26 23 20
30-40 236.78 4 54 43 34 28 50 40 32 26 35 28 23 30 25 21 26 21 18 15
40-50 336.66 5 49 37 29 23 46 35 27 22 31 24 19 26 21 17 23 18 15 12
50-60 421.68 6 45 33 25 19 42 31 23 18 27 21 16 23 18 14 20 16 12 10
60-70 485.34 7 41 29 22 16 38 28 20 15 24 18 14 21 16 12 18 14 10 8
70-80 517.29 8 38 26 19 14 36 25 18 13 22 16 12 19 14 10 16 12 9 7
80-90 513.72 9 35 24 17 12 33 23 16 11 20 14 10 17 12 9 15 11 8 9
90-100 468.70 10 33 22 15 11 31 21 14 10 18 13 9 16 11 8 14 10 7 5
100-110
352.77
110-120 200.85
Zonal Lumen Summary
120-130 73.54
Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 11.28 0-30 211.19 4.4 5.5 90-120 1022.32 21.3 26.7
140-150 1.12 0-40 447.97 9.3 11.7 90-130 1095.85 22.8 28.6
150-160 0.31 0-60 1206.31 25.1 31.5 90-150 1108.26 23.1 28.6
160-170 0.06 0-90 2722.64 56.7 71.1 90-180 1108.63 23.1 28.9
170-180 0.00 0-180 3831.28 79.8 100.0
Code•Master
PLT Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
* Photometric data is based on a fixture with a 32 W compact fluorescent PL-T lamp (2,400 lumens). For candlepower values of fixtures with 26 W PL-T lamps (1,800 lumens), multiply by 0.75. For
candlepower values of fixtures with a 42 W PL-T Lamp (3,200 lumens), multiply by 1.34. ** Photometric data is based on a fixture with two 32 W Compact Fluorescent PL-T lamps (2,400 lumens each).
For candlepower values of fixtures with two 26 W PL-T lamps (1,800 lumens each), multiply by 0.75. For Candlepower values of fixtures with two 42 W PL-T Lamps. (3,200 lumens each) multiply by 1.34.
NEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 4X
Suitable for use in wet locations
CEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
CSA 4X
Fixtures are for use with Group B atmospheres only when used with Group B mounting hoods. For 26 W,32 W, and 42 W fixtures only.
FLUORESCENT/AREA: NEC/CEC EXPLOSIONPROOF
Visit our website at www.emerson.com or contact us at (800) 621-1506.