Cut Sheet

Photometric Data
Total Luminaire Efficiency = 67.2%
REPORT NUMBER: CMBF64DD
64 W (two 32 W lamps) Fluorescent Fixture with Globe and
Deep Dome Reflector **
CIE Type - Direct
Plane
Spacing
Criteria
Maximum Candela = 933
Located at Horizontal Angle = 0, Vertical Angle = 7.5
#1 – Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (7.5)
(Through Max. Cd.)
0-180 1.44 Coefficients of Utilization - Zonal Cavity Method
90-270 1.44 Effective Floor Cavity Reflectance 0.20
Diagonal 1.60 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 80 80 80 80 78 78 78 78 75 75 75 71 71 71 69 69 69 67
0-10 88.95 1 73 70 67 65 71 68 66 63 66 63 61 63 61 60 60 59 58 56
10-20 260.61 2 66 61 56 52 65 59 55 52 57 53 50 55 52 49 53 50 48 47
20-30 413.34 3 60 53 47 43 59 52 47 43 50 45 42 48 44 41 46 43 40 39
30-40 539.82 4 55 47 41 36 53 46 40 36 44 39 35 42 38 35 41 37 34 33
40-50 630.36 5 50 41 35 31 49 41 35 30 39 34 30 38 33 30 37 33 29 28
50-60 641.74 6 46 37 31 26 45 36 30 26 35 30 26 34 29 26 33 29 25 24
60-70 436.60 7 43 33 27 23 41 33 27 23 32 27 23 31 26 23 30 26 22 21
70-80 164.84
8 40 30 24 20 38 30 24 20 29 24 20 28 23 20 27 23 20 19
80-90 47.37
9 37 28 22 18 36 27 22 18 26 21 18 26 21 18 25 21 18 16
90-100 1.92 10 34 25 20 16 34 25 20 16 24 19 16 24 19 16 23 19 16 15
100-110 0.00
110-120 0.00 Zonal Lumen Summary
120-130 0.00 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.00 0-30 762.91 15.9 23.7 90-120 1.92 0.0 0.1
140-150 0.00 0-40 1302.73 27.1 40.4 90-130 1.92 0.0 0.1
150-160 0.00 0-60 2574.82 53.6 79.8 90-150 1.92 0.0 0.1
160-170 0.00 0-90 3223.63 67.2 99.9 90-180 1.92 0.0 0.1
170-180 0.00 0-180 3225.55 57.4 100.0
Total Luminaire Efficiency = 58.9%
REPORT NUMBER: CMBF64HB
64 W (two 32 W lamps) Fluorescent Fixture with Globe and High Bay Reflector **
CIE Type - Direct
Plane
Spacing
Criteria
Maximum Candela = 2540
Located at Horzonatl Angle = 0, Vertical Angle = 5
#1 – Vertical Plane through Horizontal Angles (0-180)
(Through Max. Cd.)
#2 – Horizontal Cone through Vertical Angle (5)
(Through Max. Cd.)
0-180 0.82 Coefficients of Utilization - Zonal Cavity Method
90-270 0.82 Effective Floor Cavity Reflectance 0.20
Diagonal 0.92 % Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zone Lumens 0 70 70 70 70 68 68 68 68 65 65 65 63 63 63 60 60 60 59
0-10 239.15 1 66 64 63 61 65 63 62 60 61 59 58 58 57 57 56 56 55 54
10-20 599.67 2 62 59 56 54 61 58 55 53 56 54 52 54 52 51 52 51 50 49
20-30 645.20 3 58 54 51 48 57 53 50 47 51 49 47 50 48 46 49 47 45 44
30-40 625.54 4 55 50 46 43 54 49 45 43 48 44 42 46 44 42 45 43 41 40
40-50 452.95 5 51 46 42 39 50 45 41 39 44 41 38 43 40 38 42 39 37 36
50-60 185.71 6 48 42 38 35 47 42 38 35 41 37 35 40 37 35 39 36 34 33
60-70 58.40 7 46 39 35 32 45 39 35 32 38 35 32 37 34 32 37 34 32 31
70-80 15.26 8 43 37 33 30 42 36 32 30 36 32 30 35 32 29 34 31 29 28
80-90 4.25 9 41 34 30 28 40 34 30 28 33 30 27 33 30 27 32 29 27 26
90-100 0.69 10 38 32 28 26 38 32 28 26 31 28 26 31 28 25 30 27 25 25
100-110 0.00
110-120 0.00 Zonal Lumen Summary
120-130 0.00 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
130-140 0.00 0-30 1484.03 30.9 52.5 90-120 0.69 0.0 0.0
140-150 0.00 0-40 2109.57 43.9 74.6 90-130 0.69 0.0 0.0
150-160 0.00 0-60 2748.23 57.3 97.2 90-150 0.69 0.0 0.0
160-170 0.00 0-90 2826.12 58.9 100.0 90-180 0.69 0.0 0.0
170-180 0.00 0-180 2628.80 58.9 100.0
Code•Master
PLT Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
** Photometric data is based on a fixture with two 32 W Compact Fluorescent PL-T lamps (2,400 lumens each). For candlepower values of fixtures with two 26 W PL-T lamps (1,800 lumens each),
multiply by 0.75. For Candlepower values of fixtures with two 42 W PL-T Lamps. (3,200 lumens each) multiply by 1.34.
NEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 4X
Suitable for use in wet locations
CEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
CSA 4X
Fixtures are for use with Group B atmospheres only when used with Group B mounting hoods. For 26 W,32 W, and 42 W fixtures only.
FLUORESCENT/AREA: NEC/CEC EXPLOSIONPROOF
Visit our website at www.emerson.com or contact us at (800) 621-1506.
© May 2019
507