Cut Sheet

EBR Receptacle
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups F, G
Class III
NEMA 3, 3R, 4
, 4X
, 7CD, 9FG
DBR Receptacle
Class II, Division 1 and 2, Groups F, G
Class III
NEMA 3, 3R, 4
, 4X
, 9FG
Applications
Locations where receptacles are used with stationary or
portable electrically operated devices such as:
— Lighting systems
— Conveyors
— Heaters
— Motor-generator sets
— Air conditioners
— Compressors
— Pumps
— Locations where damp or corrosive conditions exist
Class I: classi ed locations such as:
— Petrochemical plants
— Petroleum re neries
— Paint and chemical plants
— Any location where ignitable vapors or gases are present
Class II: classi ed locations such as:
— Process industries where there are dust hazards from
handling such products as our, grain and starch or any
location where ignitable amounts of dust are present or
amounts which would adversely affect performance
Features
Energized receptacle contacts deeply recessed to reduce
danger of accidental touching.
Style 2 (shell and extra pole) grounding.
Spring door keeps dust out of receptacle when plug is not in
use. Screw cap also supplied.
Brass contacts exert constant pressure along entire contact
surface and provide superior electrical contact.
Contacts have beryllium copper wire springs.
Plug mechanical cable clamps prevent strain on cables– they
meet or exceed UL strain relief pull-out requirements.
Neoprene bushing compressed by cable collar prevents
entrance of water.
Insulators provide superior dielectric and mechanical strength
and lowest arc tracking.
1-1/2 NPT tapped conduit openings; one top to bottom.
EBRH and DBR: interlocked disconnect switch provides safe
connect and disconnect operation at 30, 60 or 100 Amp, 600
Vac maximum. Two or three pole, non-fused motor circuit
switch. EBRH permits safe operation in Class I, Group B as well
as Class I, Groups C and D, Class II, Groups F, G, and Class III
(DBR in Class II and III only).
EBR and DBR: interlocked circuit breaker provides interlocked
connect and disconnect operation as well as short circuit and
thermal time delay overload protection.
To operate, insert plug (which automatically locks into
receptacle) and turn Breaker Handle to ON position. To remove
plug, turn Handle to OFF position, lift Plug Release Knob and
pull plug out.
ACP and CPH plug ts Powertite
®
Series hazardous location
EBR, EBRH and DBR receptacles.
Standard Materials
EBR, EBRH and DBR receptacles: copperfree (4/10 of 1% max.)
aluminum receptacle and mounting box
CPH and ACP plugs: copperfree (4/10 of 1% max.) aluminum
housings
Insulating blocks: ber glass reinforced polyester
Standard Finishes
Receptacles, mounting boxes, cord connector housings and
caps: epoxy powder coat
Options
For Group B version add suf x -GB to receptacle (Group B
version not suitable for NEMA 4, 4X).
• For GE
breaker, add -GE to receptacle. Contact your local
representative for availability and price.
Molded case switch available on the 150 Amp versions, add
suf x -K to receptacle.
Special Polarization: Prevents plug insertion in a receptacle or
connector wired for a different voltage. In installations where
there are different line voltages, the special polarization option
is desirable. This allows only plugs and receptacles wired for
the same line voltage to be mated together. The receptacle
or connector interior is positioned 22-1/2°, relative to the
polarization rivet, to the right (as speci ed) of standard, and
plug is polarized to correspond. This option can be added
to receptacles using the Powertite
®
Plug. Add suf x -P4 to
receptacle or plug.
For 2" feed-thru openings (one top, one bottom) add suf x -22
to receptacle.
1 N/O and 1 N/C Auxiliary Contacts. Add suf x -AUX.
Certifications and Compliances
UL Standard: UL 1010 (UL 1203), UL 894, UL 1682, UL 1686
UL Listed: E79132, E10784, E313360(EBR)
Plugs and Receptacles
PLUGS AND RECEPTACLES: HAZARDOUS LOCATION
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© January 2011
872
EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles
With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof
600 Vac Max. 250 Vdc Max.
• Flip cover suitable for NEMA 3, 3R only.
NEMA 4 rating maintained with Appleton NEMA 4 plug installed. Select screw cover for 4, 4X. Both covers are included with product.
Add suffix -GB to Cat. No. for Group B. (Group B version not suitable for NEMA 4, 4X).
GE is a registered trademark of General Electric Company.