Cut Sheet

Class I, Division 1 and 2 Groups A, B, C, D
Class II, Division 1 and 2 Groups E, F, G
Class III
Trade
Size
(Inches)
Inches/Millimeters
Kwiko
®
A Cement
Required
Ounces/Grams
Catalog Number
Grayloy™-Iron
A (Length) B (Width)
Turning Radius
EYS Vertical and Horizontal Conduit Seals for Close Turning Radius (25% fill)
1/2" — 1"
Female

 
  EYS-11

 
  EYS-21
 
  EYS-31

 
  EYS-4

 
  EYS-5
 
  EYS-6

 
  EYS-7
    EYS-8
1-1/4" — 3" 
 
  EYS-9
 
  EYS-10
 
  EYS-012
3-1/2" — 6"
 
  EYS-014
1/2" — 1"
Male/Female (Removable Male Nipple)

 
  EYS-116

 
  EYS-216
 
  EYS-316

 
  EYS-46

 
  EYS-56
 
  EYS-66

 
  EYS-76
 
  EYS-86
1-1/4" — 3" 
 
  EYS-96
 
  EYS-106
 
  EYS-0126
3-1/2" — 6"
 
  EYS-0146
EYS
1/2" — 1"
EYS
1-1/4" — 6"
* Per NEC 501.15(C)(6), seals in Class I, Division 1 and 2 must be limited to conductor fill of 25% of cross sectional area of a rigid metal conduit of the same trade
size unless approved for higher percentage fill. See 40% fill sealing fittings.
† Turning radius with cover or plug removed.
Indicates items in the shaded area which are UL Listed for Class I, Groups A, B, C, D; Class II, Groups E, F, G; and Class III.
Fittings
FITTINGS: HAZARDOUS SEALING FITTINGS
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
182
EYS 25% * Fill Vertical and Horizontal Sealing Fittings for Close Turning Radius
Explosionproof, Dust-Ignitionproof, Raintight
UNILETS
®
for Use with Threaded Rigid Metal Conduit and IMC.

Summary of content (1 pages)