Cut Sheet

MercmasterIIIfixturesarelistedfor“SimultaneousExposure”tocombinationsofClassI,Division2andClassII,Division1hazardous
conditions.
“T” Numbers for Mercmaster III Fixtures
Lamp
Supply
Wire
Temp.
(°F/°C)
Ambient
Temp.
(°F/°C)
Class I, Division 2 Class II, Division 1 Groups E, F and G
Simultaneous Exposure
Class I, Division2 / Class II, Division 1
Watts Type Globe
Globe &
Reflector
G3
Globe
8”
Refractor Globe
Globe &
Reflector
G3
Globe
8”
Refractor Globe
Globe &
Reflector
G3
Globe
8”
Refractor
194/90 104/40 T3C T3B T3C T4A T4 T6 T3A T3 T3C
50 HPS 194/90 131/55 T3A T3A T3A T4 T3B T5 T3 T3 T3A
194/90 149/65 T3A T3 T3A T3C T3C T4A T2D T2D T3
194/90 104/40 T3B T3A T3C T4 T3C T6 T3 T3 T3A
70 HPS 194/90 131/55 T3A T3A T3B T3C T3C T5 T2D T2D T3
194/90 149/65 T3 T3A T3A T3C T3B T4A T2C T2C T3
194/90 104/40 T2D T2D T3 T3 T3A (EF) T3 (EF)
100 HPS 194/90 104/40 T3B T4A T4A T2B T2B T2C T2C
194/90 131/55 T2D T2D T3 T3 T4 T4 T2B T2B
194/90 149/65 T2D T2D T2D T2D
194/90 104/40 T2B T2B T2C T3C T2 T2B
150 HPS 194/90 104/40 T3 (EF)
194/90 131/55 T2B T2A T2B
70 PSMH
194/90 104/40 T3A T3A T3A T3C
194/90 131/55 T3A T3A T3A T3C
194/90 149/65 T3 T2 T3 T3C
100 PSMH
194/90 104/40 T3 T3 T3 T3C T2B
194/90 131/55 T3 T3 T3 T3C T2A
194/90 149/65 T2D T2D T2D T3C
150 PSMH
194/90 104/40 T2B T2B T2B T3C T2B
194/90 131/55 T2A T2A T2B T3C T2A
257/125 149/65 T2A T2 T2B T3C
175 PSMH
194/90 104/40 T2B T2B T2B T3C T2B
194/90 131/55 T2A T2A T2B T3C T2A
221/105 149/65 T2A
T2 T2B
200 PSMH
194/90 104/40 T2B T2B T2B T3B
194/90 131/55 T2B T2B T2B
250 PSMH
194/90 104/40 T2 T2 T2
194/90 131/55 T2 T2 T2
175
MH V
194/90 104/40 T2B T2B T2B T3C
194/90 131/55 T2A T2A T2B T3C
250
MH V
194/90 104/40 325 325 T2 T3B
“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp.
Range
(˚ºF)
664-
842
619-
662
574-
617
538-
572
502-
536
448-
500
421-
446
394-
419
358-
392
331-
356
322-
329
277-
320
250-
275
214-
248
187-
212
185
Temp.
Range
(°C)
351-
450
326-
350
301-
325
281-
300
261-
280
231-
260
216-
230
201-
215
181-
200
166-
180
161-
165
136-
160
121-
135
101-
120
86-
100
85
All Class II T Numbers are E, F, G unless otherwise indicated.
V CSA Certification Only.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class I, Zone 2, AEx nR IIC (ZB)
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Lighting
Lighting: EncLosEd and gaskEtEd — arEa — hid
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© October 2012
946
Mercmaster
III HID 50-250 Watt Luminaire Thermal Performance
Class I, Division 2; Class II, Division 1; Simultaneous Exposure to Hazardous Conditions of Both Classifications
Temperature Identification Numbers of Mercmaster III fixtures.