Cut Sheet
Industrial Mercmaster
™
LED Low Profile Luminaires
For Ordinary Locations
NEC/CEC:
cCSAus Listed
Type 3R, 4, 4X
IP66/IP67
NEC/CEC:
Simultaneous Exposure
Suitable for Use in Wet Locations
Marine Outside Type (Salt Water)
For USA ONLY
LED/ArEA: NEC/CEC, ATEX/IECEx ENCLosED AND GAskETED
Visit our website at www.emerson.com or contact us at (800) 621-1506.
© March 2018
1
Applications
• Enclosedandgasketedxturessuitableforusein:
—Awiderangeofharshindustrialenvironments
—Marineandwetlocations
—Areasoflowclearance,lowceilingheightsorwherexture
weightsmustbeminimized
—Areaswheredust,water,dirtandroughusageareaproblem
• Typicalindustriesinclude:
—Pulpandpapermills
—Processingplants
—Storagefacilities
—Manufacturingplants
—Foundries
—Wastetreatment
—Warehouses
—Receivingareas
• Typicalapplicationsinclude:
—Walkways/catwalks
—Stairwells
—Tunnels
—Piperacks
—Processingareas
Features
• Compactlightweightlowproledesignissuitedforlow
mountingheights.
• Choiceofcolortemperature(CCT):5000Kcoolwhite,4000K
neutralwhiteor3000Kwarmwhite.
• Sixstandardmountinghooddesignsallowformountingin
anylocation.UsessamemountinghoodsasMercmaster™III,
Mercmaster™PremiumLEDandMercmaster™Generation3.
• Customizetotheapplicationrequirementswithfour
differenteldreplaceableglobeoptions:clearanddiffused
polycarbonate,clearglass,orprismaticglassrefractor.
• RetrotadaptersforCrouseHinds
™
hoodavailable.See
Mercmaster™CHAdapters.
• RetrotadaptersforMercmaster™IIhoodsavailable.See
Mercmaster™IIAdapters.
• ThreelightoutputlevelsforretrotofHIDxturesupto175W.
• Hingehashighlipforaddedsafetyduringinstallation
andservicing.Hingeandboltconstructionassures360°
compressionatallpointsonxturehousinggasketforpositive
sealing.Swingawaydesignofcaptiveboltandnutsimplies
servicing.
• Standard6kVsurgeprotection.
• AmbientTemperature:BU:-40°Cto+65°C(-40°Fto+149°F)
BH:-40°Cupto+65°C(-40°Fupto+149°F)
• Standardscrew-typeterminalblockcanacceptUL/CSA26-10
AWGwire.
• Heavyduty,hightemperaturesiliconerubbergaskets.
• StandardNPTthreads.
• Lampliferatedat109,000Hourswithacalculatedxturelifeof
200,000hours@+25°C(+77°C).
• FieldreplaceableglobesandLEDdriver.
• Ruggedhousingwithsuperiorthermaldesigntranslatestolong
luminairelife.
Options
• Glassglobeandglassrefractorguardavailable,seeGlobes and
GasketsunderReplacement Parts.
• AllMercmaster™luminaireshaveprovisionforfusing;add
sufx–F attheendofthecatalognumber.
• Photocontrolsareavailablewithallexceptceilingandpendant
conemountinghoods.Addsufx–1for120V,–2for208V,–3
for240V,–4for277V.
Standard Materials
• Mountinghoodsandbodies:castcopperfree(4/10of1%max.)
aluminum
• Allhardwareandcatchassemblies:stainlesssteel
• Globe:polycarbonateorglass
• Refractor:heat-resistantprismaticglass
• Glassglobeguard:stainlesssteelwire
• Glassrefractorguard:diecastaluminum
• Reector:berglassreinforcedwhitepolyester
Standard Finishes
• Mountinghoods,bodiesandglassrefractorguard:grayepoxy
powdercoatnish,electrostaticallyappliedforcomplete
uniformprotection
NEC/CEC Certifications and Compliances
• ULStandard:UL1598,ThirdEdition;UL8750,SecondEdition;
• CSAStandard:No.250.0-.08;C22.2No.250.13-14
• ANSI/IECStandard:60529
• cCSAusListed:164460
Related Products
• MercmasterLEDMountingAdapters
• MercmasterGeneration3Luminaires
• IndustrialMercmasterLEDLowProleLuminaires
DesignLights
™
Consortium
• CheckDLCQPLforcurrentlistofproducts.
Nominal Lumens
HID Equivalent Model Number
3300 70-100W IMLLED2CG5BU
4400 100-150W IMLLED3CG5BU
5500 150-175W IMLLED4CG5BU
Nominal Lumen value for 5000K CCT, clear glass globe. Detailed lumen information is provided in tables.
Factory installed. (For retrofit applications, fusing must be removed from the mounting hood and ordered in the luminaire).
Available for 120-277 Vac models only. Mounting hoods with photocontrols are not rated IP66, Type 4X or Marine Outside Type (Salt Water), but are suitable
for wet locations.
Use of fuse voids Marine Outside Type (Salt Water) rating.