YOUR APRIA SLEEP THERAPY USER GUIDE For the ResMed AirSense™ 10 Use this QR link to our Sleep Apnea page for more information.
WELCOME. Thank you for choosing Apria Healthcare as your home medical provider. You are receiving this package because your doctor has diagnosed you with sleep apnea and prescribed Positive Airway Pressure therapy. Positive Airway Pressure therapy—also known as PAP therapy or sleep therapy—helps millions of users feel more energized and refreshed. We are excited to accompany you on your journey to a better night’s sleep! Responsive. On Time. Apria Delivers. With over 275 branch locations in the U.S.
Make sure your home address can be easily seen from the street during both day and night. If you are expecting a night delivery or visit, turn on the porch light. Check to see that your address numbers are easy to spot and read from the street. This will allow all Apria Healthcare and emergency services to locate your residence easily. Follow Emergency and Natural Disaster Instructions In the event of an emergency or natural disaster, follow the radio or television instructions of your local authorities.
STEP 1 GET STARTED. Start your therapy tonight so you can feel refreshed in the morning. 1. Open the box and unpack your PAP machine, humidifier chamber, tubing, mask, power cord and supplies. 2. Attach the power cord and tubing to the PAP machine. 3. Fill the humidifier with distilled water and insert the humidifier into the PAP machine. (It is recommended that you use distilled water.
STEP 2 GET FAMILIAR WITH YOUR PAP EQUIPMENT. If your doctor prescribed a specific mask and size, follow the fitting instructions provided by the manufacturer, then proceed to Step 3. If you received a mask with multiple cushions, follow the instructions below and on the next page. There is a mask cushion currently attached to the frame of your mask. This size fits most patients.
1. 2. 4. 5. 3. Nasal Mask 1. Release the lower strap magnets from the frame of the mask. Make sure the logo on the headgear is facing outward. While holding the mask against your face, pull the headgear over your head. 2. Position the lower straps so they both sit below the ears. Bring each of the magnets up to meet their corresponding clips on the frame. 3. Adjust the fastening tabs on the upper straps until the mask feels even and stable. Do not overtighten. Reattach the fastening tabs. 4.
1. 2. 3. 4. 5. 6. Nasal Pillow Mask 1. Hold the pillows away from your nose with the left (L) and right (R) indicators correctly facing towards you. 2. Guide the nasal pillows into your nostrils. 3. Pull the headgear over your head by holding the bottom strap and stretching it around the back of your head. 4. Adjust the top and bottom straps. The top strap should fit comfortably on the top of your head. 5.
1. 2. 3. 4. 5. 6. Full Face Mask 1. Twist and pull both magnetic clips away from the frame. With the logo on the headgear facing outward, hold the mask against your face and pull the headgear over your head. 2. Bring the lower straps below your ears and attach the magnetic clip to the frame. 3. Undo the fastening tabs on the upper headgear straps. Pull the straps evenly until the mask is stable and positioned as shown in the illustrations. Reattach the fastening tabs. 4.
How to Attach Oxygen to Your PAP Machine If you are using non-heated tubing, and you are also using prescribed oxygen, follow these instructions. Attach the oxygen tee adapter that was included in the box to your PAP machine. Next, attach the large-bore PAP tubing to the oxygen tee adapter. Finally, connect the small-bore oxygen tubing to the oxygen tee adapter. For detailed instructions on oxygen use, you should also review the PAP and oxygen manufacturer’s user guides included in your package.
If You Have ClimateLineAir™ Heated Tubing: 1 Attach using the illustrations and directions provided here. 1. Make sure the machine is turned on. 2 2. Hold the orange cuff of the air tubing and line up the air tubing connector with the connector port. 3. Push the cuff until the connector clicks into place. “ClimateLineAir connected” will briefly display on the device screen. If You Have ClimateLineAir™ Oxy Heated Tubing: 3 1 Attach the oxygen using the illustrations and directions provided here. 1.
STEP 3 START YOUR PAP MACHINE. 1. First, put on your mask. Next, attach the tubing to the mask. 2. Lie down and take four deep breaths. The machine should start automatically. If you do not hear the machine start, press the Start/Stop button. Relax and begin to take slow breaths through your nose. 1 3. Check for air leaks. Small leaks are acceptable. If large leaks occur, try the following: • Grasp the mask frame and lift it away from your face. The cushions should also lift off your face.
Helpful Tips For Nasal and Full Face Masks • To resolve leaks at the upper part of the mask, adjust the upper headgear straps. • For leaks at the lower part, adjust the lower headgear straps. • When adjusting straps, loosen or tighten both the left and right straps so that adjustments are made evenly. • Adjust only enough for a comfortable seal. • The upper strap adjustment is the key to seal and comfort. • Do not overtighten the lower straps. They mainly serve to keep the cushion in position.
GET COMFORTABLE WITH YOUR THERAPY. Use your PAP therapy during all hours of sleep, including during naps. Some people may need up to one or two weeks to adjust to PAP therapy, but the benefits are well worth it. Ways to help you adjust: • Try watching TV or reading while wearing your mask and headgear. Turn on the PAP device for short periods of time while wearing your mask to get used to the pressure. • Use your equipment every night.
14 TRACK STEP 3:YOUR STARTPROGRESS YOUR PAP MACHINE Questions? Call 888.452.
TRACK YOUR PROGRESS. You can track your progress by registering for ResMed’s myAir™ application at www.resmed.com/myAir or by downloading the myAir™ by ResMed app from the App Store on your smartphone. You can view your daily sleep score and previous night’s results. You can also access other helpful information, like videos and guides designed to help you stay motivated in adhering to your PAP therapy. Note: Data will be available following the first night using the machine after you register.
GET SUPPORT. If you are having difficulties getting used to therapy, try using your machine’s “comfort features” to help. Do you have a dry nose or throat, or a runny nose? Increase the humidity level. Are there droplets of water or condensation inside your nose, mask, or tubing? Decrease the humidity level. How to Change the Humidity Level: This information is intended for your general knowledge only and is not a substitute for medical advice or treatment for a specific medical condition.
Is the air pressure making it difficult for you to fall asleep? Turn on the Auto Ramp or increase the Ramp Time. Do you feel bloated? You may be swallowing air. Turn on the Auto Ramp or increase the Ramp Time. Do you feel like you are not getting enough air? Turn the Ramp Time to “off.” How to Change the Ramp Time: Do you have sore or dry eyes? Adjust your mask or headgear. It may need to be repositioned. Refer to the instructions provided in the manufacturer’s user guide for your mask.
CLEANING, MAINTENANCE AND REPLACEMENT 1. Oil from your face and ingredients in facial products can cause the PAP mask cushions to wear down and decrease the useful life of the mask. Get in the habit of wiping down your mask each day, especially the areas that come in contact with your skin. Clean your mask and headgear weekly according to the instructions in the mask user guide. 2. Wash the water chamber and air tubing in warm water, using a mild detergent. Hand wash only.
REPLACE SUPPLIES REGULARLY Replace your sleep supplies regularly. This helps to ensure a good mask seal and reduce buildup of bacteria, viruses, and allergens.1 Ordering fresh, clean supplies to replace your old items helps improve the comfort of your mask and maintains the overall effectiveness of your therapy.
Apria’s customer service team of Kaiser Permanente experts can be contacted 24 hours a day, seven days a week: 888.452.4363 Apria is committed to safe, quality patient care. We encourage you to report any concerns to your local Apria Healthcare branch. If your concern is not resolved, please contact the Patient Satisfaction team at the number listed below. 800.260.8808 ClimateLineAir and myAir are trademarks and/or registered trademarks of the ResMed family of companies.