a hard disk is congured as slave and if a CD/DVD drive or no drive at all
is connected at the same IDE channel as master. Normally, EZ Gig can
handle that, too.
NOTE: If an SATA hard disk is not recognized, this can also be due to the
used SATA controller.
IDE controller not found
There are the following three reasons why EZ Gig has not automatically
recognized an IDE controller:
The IDE controller/channel is deactivated, e.g. on an onboard IDE
controller. Activate the IDE controller/channel via the BIOS setup.
Standard IDE controllers (ISA) are not taken into account if PCI
IDE controllers are available. Connect the respective hard disk to a
PCI IDE controller in this case or deactivate the PCI IDE controller
or controllers.
The used controller does not correspond to the PCI IDE standard.
Although most controllers support this standardized programming
interface, there are some controllers which have only a proprietary
programming interface. Connect the corresponding drives to
another controller (PCI IDE controller).
Source & Destination Size Differences
Equal Size
If source and target are of the same size, EZ Gig creates an absolutely
identical copy(clone). On this clone, all sectors on source and target, from
the rst to the last sector, are 100% identical, provided that the process
was error-free.
Small to large
If the source is smaller than the target, EZ Gig copies only the data that
is available on the source. This data is copied from the beginning of the
source onto the beginning of the target medium. The area at the end of
the target medium, which is larger than the source, remains unaffected.
Apart from that the unaffected area remains possibly unused during a later
usage, such a copy is usually comparable to a real clone as far as the
capacity of use is concerned because the target contains entirely all data of
the source
Large to small
If the source is bigger than the target, EZ Gig will direct you to the Data
Select feature. EZ Gig’s Data Select provides a simple method to deselect
data folders from the cloning process. EZ Gig will only allow to proceed
with the clone, once the available capacity on the target drive is a positive
value.
Automatic troubleshooting
In case of occurring errors, EZ Gig tries to troubleshoot them the
best possible. If this is not possible, the errors will be mentioned in a
corresponding error statistic in the detailed report after the clone is
complete.
Intensive reading/writing
In case of read or write errors, EZ Gig uses different strategies in order
to still be able to read or write this data, if possible. The time used for
defective areas depends to a large extent on the respective medium.
According to the medium and its state, several seconds up to minutes can
be needed for the recovery trials. Therefore, it is recommended to always
activate the option SafeRescue because then handling defective sectors
takes place after the copying of all intact areas has been nished. The
process can then be aborted if it takes too long without losing the data of
the intact areas.
Read errors
During the copying process, read errors can only occur on the source
medium. EZ Gig then tries to read the defective areas immediately after
the termination of the copying process (with the option SafeRescue) with
the help of special data recovery strategies within a single troubleshooting
run. During the troubleshooting run, the number of the indicated read errors
can reduce according to the areas on the source medium, which could be
recovered.
NOTE: Read errors, that occur during the verication run, are not counted
as read errors but as verication errors.
Write errors
Write errors can only occur during the copying process and only on the
target medium. EZ Gig then tries to read the defective areas immediately
after the termination of the copying process (with the option SafeRescue)
with the help of special data recovery strategies within a proper
troubleshooting run. During the troubleshooting run, the number of the
indicated write errors can decrease according to the areas on the target
medium, which could be recovered.