Install Instructions

MOUNTED TO THE JOIST HUNG FROM THE JOIST
AIR FLOW
MOUNTING BRACKET LOCATIONS
MOUNTED TO WALL OR FLOOR JOISTS
90-2060
FIGURE 4 – MOUNTING BRACKET POSITIONING
VENTILATOR LOCATION AND ORIENTATION
CAUTION
1. Mount the blower with the lowest, exposed moving parts at least 8 feet (2.4 m)
above floor or grade level.
2. Mount the blower at least 3.3 feet (1.0 m) from any accessible opening of the duct.
Choose a location for the ventilator that is within 6 feet of the outlet into which the
ventilator will be plugged. Allow space for filter removal and service as shown in FIGURE 2.
8140 installations: The ventilator can mounted in any orientation.
8141 installations: To ensure proper operation of the backdraft damper on the outlet collar,
mount the ventilator with the outlet collar either horizontal as shown below, or angled up.
After deciding which orientation the ventilator will be installed, make sure the pivot of the
backdraft damper is located above the centerline of the collar (see FIGURE 3) to ensure
that it closes when the ventilator is off. Remove the outlet collar and rotate it 180° if needed
to make sure the backdraft damper functions properly.
10"
FILTER
ACCESS
24"
MOTO R
ACCESS
90-2121
FIGURE 2 – CLEARANCES FOR SERVICING
CORRECT INCORRECT
DAMPER PIVOT
CENTERLINE OF COLLAR
90-2121
FIGURE 3 – OUTLET COLLAR ORIENTATION
MOUNT THE VENTILATOR
1. Install the mounting brackets, using the #8 x 1/2" screws supplied, to the side of the housing as shown in FIGURE 4. Use the holes nearest the
covers for mounting to floor joists or hanging from rafters. Use the holes near the bottom of the unit for mounting to a flat wall or ceiling surface.
2. Secure the ventilator into joists or a strong platform and screw into place using the #10 x 3/4" screws provided. The ventilator weighs
approximately 25 pounds, so do not secure it into drywall alone.
3. Make sure the backdraft damper in the oval outlet collar is positioned so that it will open when the ventilator is on and will close on its own when
the ventilator is off. If necessary, remove the collar, rotate it 180° and reinstall.
3