Installation guide

System Installation Guide
10
69-2688—03 I/O-CHTSTAT03
Entry/Exit Remote or Vent Boost Remote
Press and release CONNECT button.
TrueSTEAM
Press and release the CONNECT button on the THM4000 Wireless Adapter. After a short delay, the CONNECTED status light will glow
steady green..
Link optional accessories to wireless network
4
MCR32943
RedLINK Internet Gateway
Press and release the button on the bottom of the Internet
Gateway. After a short delay, the RedLINK status light will glow
steady green.
The Internet Gateway must be registered online before
use at www.mytotalconnectcomfort.com. Enter the MAC
ID and MAC CRC numbers located on the bottom of
the Internet Gateway. For additional information, see
instructions provided with the device.
MCR32942
CONNECT
WIRELESS SETUP
Portable Comfort Control
The linking procedure will time out if there is no keypress for 30 minutes. To begin again,
press and hold in the lower right corner of the screen until the display changes (about 3
seconds).
Press CONNECT on the Portable Comfort Control display screen. Press DONE when the
screen displays "Connected." Press NO at the next screen to save and exit. (Or press
YES to link another thermostat.)
Error messages:
E1 29
Incompatible device cannot be connected.
E1 34 Low RF signal. Move device to a different location and try again.
E1 38 Make sure the thermostat is in Wireless Setup mode,
and the Portable Comfort Control is at least 2 feet away (600 mm).
MCR33096
After a short delay, the status light will glow
green for 15 seconds. If the status light
turns red, the remote did not link with the
thermostat for the connection process.