User Guide

59
use and maintenance Atlantic 500
1
2
CHECKING BATTERY FLUID
LEVEL
To check the battery fluid level:
Remove the battery cover, see page 58
(REMOVING THE BATTERY COVER).
Make sure that battery fluid level is
between the MIN and MAX marks on the
battery.
If not so:
Remove the battery caps.
Top up with distilled water only. Do not
exceed the MAX mark, because battery fluid
expands when the battery is under charging.
Add distilled water until achieving correct
level.
CHARGING THE BATTERY
Remove the battery, see page 58
(REMOVING THE BATTERY).
Remove the battery caps.
Check battery fluid level, see (CHECKING
BATTERY FLUID LEVEL) at the side.
Connect the battery to a battery charger.
Recommended charge rate is 1/10th of
battery capacity.
After charging the battery, check battery
fluid level again. Top up with distilled water
if needed.
Refit the caps.
The battery keeps producing gases for some
time after the battery charger has been
switched off. Allow 5-10 minutes before
proceeding to refit the battery.
INSTALLING THE BATTERY
Remove the battery cover, see page 58
(REMOVING THE BATTERY COVER).
Place the battery into its mount.
Make sure to connect the battery breather
hose, to prevent sulphuric acid vapours
from corroding electric components, paint-
finished and rubber parts, and seals.
Connect the positive cable (+) first and
then the negative cable (-). Tighten terminal
screws.
Coat the battery lead connections and
terminals with neutral grease or Vaseline.
Connect the battery breather hose (1).
Refit the battery cover, see page 58
(REMOVING THE BATTERY COVER).
CAUTION
CAUTION
CAUTION