Specifications
Electrical system
chap. 6
6-3
6
Release 00 2002-09
Atlantic 500
CHECKING THE ALTERNATOR CONTINUITY
With the engine off:
• Remove the right side panel, see (REMOVING
THE SIDE PANELS).
• Disconnect the regulator wires connector (1).
• Using a portable tester, test the continuity be-
tween the yellow wires (G) of the stator.
• Also, check the isolation of the stator support.
Standard resistance: 0.1 - 1 Ω
Standard resistance between wires and stator
support: ∞ (infinity)
VOLTAGE REGULATOR
• Remove the rear part of the fairing, see (REMOV-
ING THE REAR PART OF THE FAIRING).
• Remove the right side panel, see (REMOVING
THE SIDE PANELS).
• Disconnect the connectors (1) and (2).
• Using a portable tester (scale x 1 kΩ), test (from
the regulator side) the resistance between the
wires indicated in the table below.
• If the resistance reading is incorrect, change the
regulator.
Tester positive terminal (+) on:
Tester negative terminal (-) on:
123 45 6 7
1 ∞∞ ∞∞ ∞ ∞
2 ∞∞∞∞∞∞
3 ∞∞ ∞∞ ∞ ∞
4 ∞∞∞ ∞ 0 ∞
5 ∞∞∞ ∞ ∞ 0
6 ∞∞∞ 0 ∞∞
7 ∞∞∞ ∞0 ∞
CAUTION
This inspection method is only approximate.
If possible, substitute a voltage regulator that you
know works, to check the charging circuit.
1
1
1
2
4
5
6
7
1
2
3