Technical data

Electrical Equipment
chap. 6
6-30
Release 00 2002-09
Atlantic 500
AIR TEMPERATURE SENSOR
To verify that the air temperature sensor works:
Disconnect the two-way connector (1).
Carry out the sensor check in an environment with
controlled temperature of 20 °C (68 °F).
Measure the electrical resistance with an ohm
meter (scale 0-20 k) between the connector
terminals (1).
Correct value: 12.200 k
- 12.700 k
If the air temperature sensor works correctly check the
dashboard:
Apply a resistance equal to 12.4 k between the
sensor terminals (cabling side).
If the dashboard works correctly it should indicate
a temperature of 20 ± 1 °C (68 ± 3 °F).
1
1
+-