CHECKING THE ELECTROLYTE LEVEL
To check the electrolyte level, proceed as follows:
Remove the battery cover, see (REMOVING THE
BATTERY COVER).
Make sure that the fluid level is included between
the two MIN and MAX notches stamped on the
battery side.
Otherwise:
Remove the element plugs.
Top up with distilled water only. Do not exceed the
MAX mark, since the electrolyte level increases
during the recharge.
Top up by adding distilled water.
RECHARCING THE BATTERY
Remove the battery, see (REMOVING THE
BATTERY). Remove the element plugs.
Remove the element plugs.
Check the electrolyte level, see beside (CHECK-
ING THE ELECTROLYTE LEVEL).
Connect the battery with a battery charger.
A recharge with an amperage equal to 1/10th of
the battery capacity is recommended.
After the recharging operation, check the electro-
lyte level again and if necessary top up with
distilled water.
Put back the element plugs.
Reassemble the battery only 5-10 minutes after
disconnecting the recharger, since the battery
continues to produce gas for a short lapse of time.
CAUTION