Technical data
Electrical Equipment
chap. 6
6-9
6
Release 00 2002-09
Atlantic 500
CONNECTIONS TO THE E.C.U. CONTROL UNIT
COMPONENT
RPM sensor 7 - 12 680 Ω B - B/N
Stepper Motor 14 - 24 52 Ω Az - Ro
Stepper Motor 6 - 21 52 Ω Vi - G
Accelerator sensor 1 - 22 5 kΩ M/Bi - Gr
Accelerator sensor 1 - 11 1 - 6 kΩ M/Bi - M/G
Air injection terminals 18 - 22 see tab. Ro/N - Gr
Water injection terminals
4 - 22 see tab. Ar - Gr
Drop sensor 16 -22 62 kΩ * Ro/G - Gr
Coil 20 0.6 Ω Ar/Bi - R/M
Injector 13 14.5 Ω Gr/R - R/M
TERMINALS
NOMINAL
VALUE
CABLE COLOUR
* With drop sensor in upright position.