Technical data

Electrical Equipment
chap. 6
6-10
Release 00 2002-09
Atlantic 500
CHECKING THE HV COIL
Remove the left inspection cover, see
(REMOVING THE RIGHT AND LEFT
INSPECTION COVERS).
Disconnect terminal (1).
Unscrew and remove the two screws (2).
Disconnect the spark plug (3).
Remove the coil (4).
4
1
2
With a pocket multimeter (scale 200 ), measure
the resistance (from the coil side) between the
terminals (A e B) indicated in the diagram.
If the resistance measured is not correct, replace
the coil.
Standard value: 0.6
± 0.1
Also verify the resistance between the high
voltage terminal and the casing of the coil.
Standard value: 7.4 k
Before measuring, remove the H.V. cable complete
with the spark plug cap.
A
B
CAUTION
3