Technical data

Electrical Equipment
chap. 6
6-13
6
Release 00 2002-09
Atlantic 500
THROTTLE VALVE POTENTIOMETER
(ACCELERATOR SENSOR) CHECK
With motor off:
Disconnect the three-way connector (black) (1).
During reassembly ensure correct coupling of the
electrical connector (1).
Set the ignition switch to
.
With a multimeter (scale k), measure the
resistance between the potentiometer terminals.
MEASUREMENT (A)
Resistance between the two terminals A and B, in any
position of the throttle valves:
Standard value: 5 k
± 10%
MEASUREMENT (B)
Resistance between the terminals A and C:
From the value of the throttle completely closed,
accelerating progressively up to completely open, the
resistance will vary as follows:
Standard value: from 1 k
to 6 k
± 10%
NOTE To unscrew the two screws more easily, block
with LOCTITE
®
243, preheat with a blow of hot air.
Unscrew and remove the screws.
Remove the potentiometer.
If the resistance values are different from those
prescribed, replace the potentiometer.
CAUTION
A
B
C
1