INJECTOR CHECK
With motor off:
Disconnect the two-way connector (1) (black) and
take measurements (on the terminals on the
injector side).
With a multimeter (scale x 100 ), measure the
resistance between the injector terminals.
Standard value: 14.5 ± 10%
to 25°C
If the resistance is infinite () or less than the
prescribed value, the injector (2) must be
replaced.
COOLANT THERMISTOR FUNCTION CHECK
Remove the thermistor (1), see (COOLANT
THERMISTOR REMOVAL).
Connect a multimeter (2) (set in ohm metre mode)
as illustrated in the diagram, to the thermistor (1).
Immerse the thermistor (1) in a container (3)
containing coolant.
In the same container immerse a thermometer (4)
with 0 -150 °C gauge (32 -302 °F).
Place the container on a hotplate (5) and slowly
heat the liquid.
Check the temperature indicated on the
thermometer (4) and the value of the thermistor
(1) indicated on the multimeter.
Verify that the values vary in relation to the temperatu-
re as indicated.
NOTE If the standard values do not change as the
temperature changes, or change too much from those
given in the table, replace the thermistor (1).
Repeat these operations also for the other
thermistor.
Temperature °CA1 - A2 ()
B1 - B2 ()
60 557 ±10% 576 ±10%
90 196 ±10% 231 ±10%
120 80.6 ±10% 105 ±10%