Technical data
Electrical Equipment
chap. 6
6-14
Release 00 2002-09
Atlantic 500
INJECTOR CHECK
With motor off:
• Disconnect the two-way connector (1) (black) and
take measurements (on the terminals on the
injector side).
• With a multimeter (scale x 100 Ω), measure the
resistance between the injector terminals.
Standard value: 14.5 ± 10%
ΩΩ
ΩΩ
Ω to 25°C
If the resistance is infinite (∞) or less than the
prescribed value, the injector (2) must be
replaced.
COOLANT THERMISTOR FUNCTION CHECK
• Remove the thermistor (1), see (COOLANT
THERMISTOR REMOVAL).
• Connect a multimeter (2) (set in ohm metre mode)
as illustrated in the diagram, to the thermistor (1).
• Immerse the thermistor (1) in a container (3)
containing coolant.
• In the same container immerse a thermometer (4)
with 0 -150 °C gauge (32 -302 °F).
• Place the container on a hotplate (5) and slowly
heat the liquid.
• Check the temperature indicated on the
thermometer (4) and the value of the thermistor
(1) indicated on the multimeter.
Verify that the values vary in relation to the temperatu-
re as indicated.
NOTE If the standard values do not change as the
temperature changes, or change too much from those
given in the table, replace the thermistor (1).
• Repeat these operations also for the other
thermistor.
Temperature °CA1 - A2 (Ω)
B1 - B2 (Ω)
60 557 ±10% 576 ±10%
90 196 ±10% 231 ±10%
120 80.6 ±10% 105 ±10%
A1
B2
B1
A2
1
1
2