Technical data

Electrical Equipment
chap. 6
6-15
6
Release 00 2002-09
Atlantic 500
FUEL PUMP CHECK
Supply terminals 1 and 4 of the pump connector
with a 12V tension (c.c.).
Verify that the pump works, emitting the
characteristic hum, and check on the manometer
that the supply pressure reaches at least i 150
KPa (1.5 bar).
Observe the pump polarity.
CAUTION
AIR THERMISTOR FUNCTION CHECK
During reassembly ensure the correct coupling of
the electrical connector (1).
Remove the thermistor (2).
Connect a multimeter (3) (set to ohm meter mode)
al thermistor (2), as illustrated in the diagram.
Immerse the thermistor in a container (4)
containing water.
In the same container immerse a thermometer (5)
with 0 -150 °C gauge (32 -302 °F).
Place the container on a hotplate (6) and slowly
heat the liquid.
Check the temperature indicated on the
thermometer (5)and the value of the thermistor
indicated on the multimeter.
Verify that the values vary in relation to the temperatu-
re as indicated.
CAUTION
Temperature °C
0 9750
10 5970
20 3740
30 2410
Resistance
NOTE If the values do not change as the temperatu-
re changes, or change too much from those given in
the table, replace the thermistor (2).
1
2
(direct current)