Technical data

Electrical Equipment
chap. 6
6-17
6
Release 00 2002-09
Atlantic 500
STARTING RELAY CHECK
Disconnect the two-way connector (1)(white).
During reassembly ensure correct coupling of the
electrical connector (1).
Pull the relay out from the special hooks (2).
Pull out the two rubber protectors (3-4).
Disconnect the cables from their respective
terminals on the relay (2).
Supply the two internal terminals to the connector
(1) with a 12V tension from the relay side.
With a multimeter (set to Ohm meter mode) verify
the continuity between the two screw contacts on
the relay (2).
Correct value with supply to the relay: 0
Correct value without supply to the relay:
If the resulting values do not correspond to those
prescribed, replace the relay (2).
CAUTION
STOP LIGHTS RELAY CHECK
To verify that the relay is working:
To access the relay raise the saddle and remove
the left tail lamp, see (TAIL LAMP BULBS
REPLACEMENT).
Supply the two male terminals (85-86) with a 12V
tension;
With a multimeter (set to ohm meter mode) verify
the continuity between the other two terminals (87-
30).
Correct value with supply to the relay: 0
Correct value without supply to the relay:
If the resulting values do not correspond to those
prescribed, replace the relay concerned.
1
3
2
4