Technical data
Electrical Equipment
chap. 6
6-22
Release 00 2002-09
Atlantic 500
WATER TEMPERATURE
DASHBOARD CHECK
• Disconnect the water thermistor connector and
connect an electrical resistance (from the connector
side) between the orange/red and white/black cables.
• Turn the key to ON and verify the indication on the
dashboard.
Connector values:
resistance <60 Ω bottom scale indication
resistance 80 Ω start of red zone indication
±5°
resistance >1090 Ω start of scale indication
WATER THERMISTOR CHECK
See (COOLANT THERMISTOR FUNCTION CHECK)
pages 6-14.
FUEL LEVEL
DASHBOARD CHECK
• Disconnect the pump assembly connector and
connect an electrical resistance (from the connector
side) between the yellow-green and orange-black
cables.
• Turn the key to ON and verify the indication on the
dashboard.
Connector values:
resistance 250 Ω 1/2 scale indication
±5°
resistance 3 Ω full indication
resistance 820 Ω empty indication and indicator lit
FUEL LEVEL SENSOR CHECK
• Disconnect the pump assembly/sensor connector.
• Connect an ohm meter to terminals 2 and 3 and
verify the indication at different fuel levels.
Correct value with full tank - less than 16 Ω
Correct value with 8 litres of fuel - 300-400 Ω
Correct value with Ø litres - more than 800 Ω
VIEWED FROM ”A”
R