Datasheet

Rev1.7 2022-03-10
RSD-D
Meets NEC 2017 & 2020 (690.12) requirements
Executes rapid shutdown of system when
Transmitter-PLC signal is absent
Meets SunSpec requirements
Dual-input channel
RSD-D meets SunSpec requirements, maintaining normal function by continually receiving a heartbeat signal from the APsmart Transmitter.
The RSD-D executes rapid system shutdown when the Transmitter signal is absent. Users can manually execute rapid shutdown using
Transmitter breaker switch.
© All Rights Reserved
MODEL
RSD-D-15
RSD-D-20
INPUT DATA (DC)
Range of Input Operating Voltage
8-65V Per Channel
Maximum Cont. Input Current (Imax)
15A Per Channel
20A Per Channel
Maximum Short Circuit CurrentIsc
25A
OUTPUT DATA (DC)
Range of Output Operating Voltage
16-130V
Maximum Cont. Output Current
15A
20A
Maximum System Voltage
1000V/1500V
Maximum Series Fuse Rating
30A
MECHANICAL DATA
Operating Ambient Temperature Range
-40
o
F to +167
o
F (-40 °C to + 75 °C)
Dimensions (without cable & connectors)
5.5" x 2" x 0.8"(140 mm x 50.6 mm x 20 mm)
Cable Length
Input 500mm/Output 2400mm
Cable Cross Section Size
TUV:4mm²/UL:12AWG
Connector
Stäubli MC4 PV-KBT4&KST4 or Customize
Enclosure Rating
NEMA Type 6P/IP68
Over temperature protection
Yes
FEATURES & COMPLIANCE
Communication Compliance
PLC
Safety Compliance
NEC 2017 & 2020 (690.12); UL1741;
CSA C22.2 No. 330-17; IEC/EN62109-1
EMC Compliance
FCC Part15; ICES-003
Raising the bar in innovative
DC MLPE solar power systems
> RSD-D TECHNICAL DATA

Summary of content (2 pages)