4. THERMOSTAT CALIBRATION 
Checking Thermostat Calibration: 
The fryer thermostat is carefully calibrated at the factory so that dial settings match actual frying compound 
temperatures. Field re-calibration is seldom necessary unless the unit has been mishandled in transit or 
abused.  Re-calibration  should  not  be  resorted  to  unless  considerable  experience  with  cooking  results 
definitely proves that the control is not maintaining the temperature to which the dial is set. 
1.  To check compound frying temperatures when re-calibrating, use a precision test instrument, or a good 
grade mercury thermometer. Fill the tank half way between the MAX and MIN marks on the tank. 
2.  Frying compound temperature should be checked at the center of the tank, approximately 1” to 1 1/2” 
below surface of frying compound. 
3.  Turn the dial of the thermostat being checked to the 350°Fmark. 
4.  Allow temperature  to  stabilize,  or  until  the  thermostat  cycles  to  “OFF” three times after starting with 
cold  frying  compound.  With  power  “ON”,  read  highest  and  lowest  frying  compound temperature, as 
thermostat cycles through at least twice, average the reading. 
5.  Thermostat should be re-calibrated if temperature reading is not within 10 degrees of the control knob 
setting (350°F +/- 15°F). If re-calibration is required, continue with steps 6, 7, 8 and 9. 
6.  Remove control knob by grasping outer edge and pulling straight out, without twisting or turning. 
7.  Hold thermostat dial shaft “B” (Figure 1) stationary with pliers, and with a screwdriver, turn screw “A” 
clockwise to  obtain  a  lower  temperature;  or  counter-clockwise  for  higher temperature.  Each ¼  turn 
(90° rotation) of screw “A” represents 18°F. 
8.  Replace thermostat control knob. 
9.  Recheck thermostat as in Steps 4 and 5 above. If the fat temperature is not within 20 degrees of dial 
setting (350°F +/- 20°F), it means that the sensing element is inoperative and the thermostatic control 
should be replaced.   
FIGURE 1 
5. OPERATING 
Removing Fry Tanks: 
1.  Remove fry baskets. 
2.  Carefully grasp the element handle. CAUTION: May be hot. Pull out the head lock on the left of the 
head. 
3.  Lift  the  element  handle  while  at  the  same  time,  pulling  the  head  lock.  This  will  permit  lifting  the 
elements  to  just  above  frying  compound  level  in  tank.  The  element  can  be  left  in  this  position  for 
draining frying compound. 
4.  Again,  lift  the  element  handle  while  pulling  the head  lock,  until  the  elements  lock  themselves  at  a 
higher position. 