5. THERMOSTAT CALIBRATION
Checking Thermostat Calibration:
The  fryer  thermostat  is  carefully  calibrated  at  the  factory  so  that  dial  settings  match  actual  frying 
compound temperatures. Field re-calibration is seldom necessary unless the unit has been mishandled in 
transit or abused. Re-calibration should not be resorted to unless considerable experience with cooking 
results definitely proves that the control isn’t maintaining the temperature to which the dial is set.
1. To check compound frying temperatures when re-
calibrating, use a precision test instrument, or a 
good  grade  mercury  thermometer.  Fill  the  tank 
half way between the MAX and MIN marks on the 
tank.
2. Frying compound temperature should be checked 
at the center of the tank, approximately 1" to 1 ½" 
below surface of frying compound. 
3. Turn the dial of the thermostat being checked to 
the 350°F mark.
4. Allow  temperature  to  stabilize,  or  until  the 
thermostat  cycles  to  “OFF”  three  times  after 
starting  with  cold  frying  compound.  With power 
“ON”, read highest and lowest frying compound 
temperature,  as  thermostat  cycles  through  at 
least two cycles. Average the reading.
5. Thermostat should be re-calibrated if temperature 
reading  is  not  within  10  degrees  of  the  control 
knob setting (350°F +/- 15°F). If re-calibration is 
required, continue with steps 6, 7, 8 and 9.
6. Remove control knob by grasping outer edge and pulling straight out, without twisting or turning. 
7. Hold thermostat dial shaft “B” (Figure 1) stationary with pliers, and with a screwdriver, turn screw “A” 
clockwise to obtain a lower temperature; or counter-clockwise for higher temperature. Each ¼ turn 
(90° rotation) of screw “A” represents 18°F.
8. Replace thermostat control knob. 
9. Recheck thermostat as in Steps 4 and 5 above. If the fat temperature is not within 20 degrees of dial 
setting (350°F +/- 20°F), it means that the sensing element is inoperative and the thermostatic control 
should be replaced. 
6. OPERATING
Removing Fry Tanks (Fry tanks equipped with drain are not to be removed): 
1. Remove fry baskets. 
2. Carefully grasp the element handle. CAUTION: May be hot. Pull out the head lock on the left of the 
head. On the EF-30NT there is also a head lock on the right side of the right head. 
3. Lift  the  element  handle  while  at  the  same  time,  pulling  the  head  lock. This  will  permit  lifting  the 
elements to just above frying compound level in tank. The element can be left in this position for 
draining frying compound. 
4. Again, lift the element handle while pulling the head lock, until the elements lock themselves at a 
higher position. 
5. Firmly grasp both handles of fry tank and lift it out. After replacing the fry tank, simply pull the head lock; 
and at the same time, pull down the element handle until the elements rest on fry tank bottom. 
6. Both  the  lifting  out  and  lowering  of  elements  can  be  done  in one  swing,  without  stopping  at  the 
intermediate position.
5