Electrical Connections
Terminal Box Location:
The terminal boxes can be located at either the left front or right rear of the griddle. When shipped from the
factory the device has the terminal box attached in the left front position. The box can be relocated to the
alternate position by removing two screws.
Loading:
Electrical loadings of the griddles covered by this instruction are tabulated below.
Fusing:
Griddle is not fused and must be connected to a properly fused circuit.
Grounding:
Griddle must be grounded in accordance with the National Electrical Code and applicable local codes.
U.L. CONDITIONS OF ACCEPTABILITY:
1. This equipment must be installed in an all metal fixture of steel or stainless steel construction, .078 inch thick
minimum for the top and supporting frame. Side enclosure to be at least 22 MSG minimum thickness.
2. A removable bottom enclosure must be provided under each drop-in unit and be made of metal construction of
at least 22 MSG minimum. If ventilating openings are provided in the bottom enclosure, they must not allow the
entrance of ¾-inch diameter rod nor be located directly below uninsulated live terminals.
3. Minimum spacing between griddle top edge and adjacent items should be: fixture back wall 1 ¾ inch, fixture
side enclosure 1 inch, front control panel 7/8 inch, other drop-in devices 1 inch.
5