Product manual
4. Controls shall be mounted on the front vertical surface of the fixture.
5. For supply connections, use wire suitable for at least 90 degrees Celsuis (194 degrees Fahrenheit).
NOTES:
1. Griddle can be mounted with the trough in the front or rear, dimensions shown are for front trough mounting. For
rear trough mounting, this dimension must be between 7/8 inch and 2 inches.
2. Table top reinforcement and gasket furnished with the griddle.
3. At the factory, the electrical connection box was installed in the front position. The connection box can be moved
to the rear location shown.
IMPORTANT:
1. Any dimension smaller than the minimum or larger than the maximum shown in the table will require
corresponding changes to the grease chute by the fabricator by adding an extension to prevent the grease from
spilling into the cabinet.
2. Any dimensions smaller than minimum given will require additional panels or sides and back to facilitate
servicing.
3. The minimum dimension from the back of the control panel to the front of the griddle top is 7/8 inch regardless
of the shape of the bullnose or table overhang.
4. Griddles are shipped from the factory with dimension ”D” at 7 7/16 inch. Moveable braces permit the fabricator
to easily vary this dimension up to 10 7/16 inches in increments of ¾ inch.
5. The minimum space between adjacent griddles must be 1 5/8 inch and between any other combination of drop-
in cooking equipment must be 1 inch.
6. Electrical wiring crossing the tray slide is to be placed under the tray slide and not above it.
7. The installer or servicer must put the electrical wiring near the control panel inside the wire guide before
attaching the control panel to the fixture front.
IMPORTANT STEPS IN INSTALLATION:
1. Griddle position to be no closer than 7/8 inch from component frame edge and control panel.
2. Install the gasket between the griddle top and the table top before clamping. Exercise caution so that the griddle
top does not pinch or damage the gasket
ELECTRICAL DATA
PHASE-LOADING AND LINE AMPERES 50/60 HZ
Model
Number
3-Phase Loading
NOMINAL AMPERES PER LINE
3-Phase AC 1-Phase AC
KW Per Phase 208 VOLTS 240 VOLTS 480 VOLTS
208
VOLT
240
VOLT
480
VOLT
Y-Y Y-Z X-Z X Y Z X Y Z X Y Z AC AC AC
EGD48 21.6 10.8 5.4 5.4 69.0 69.0 45.0 60.0 60.0 39.0 30.0 30.0 20.0 104 90 45
EGD72 32.4 10.8 10.8 10.8 90.0 90.0 90.0 78.0 78.0 78.0 39.0 39.0 39.0 156 135 68
Power
Input
(KW)
6