General Installation Instructions:
Ensure gas supply and gas type, as shown on unit nameplate agree.
Unit installation must conform with the National Fuel Gas Code, ANSI Z223.1-1996, the National Gas Installation Code, CAN/CGA-
B149.1, or the Propane Installation Code, CAN/CGA-B149.2 as applicable and in accordance with local codes.
Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand. Level the unit by turning the adjust-
ment screw at the bottom of each leg. Do not slide unit with legs mounted, lift if necessary to move unit.
Pipe threading compound must be resistant to the action of liquefied petroleum gases.
Caution: DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap and water solution before oper-
ating unit.
These units are suitable for installation on non-combustible surfaces only.
Noncombustible clearances:
0” sides (0 mm) 0” rear (0 mm) 4” floor (102 mm)
Do not obstruct the flow of combustion and ventilation air, under the unit by the legs or behind the unit by the flue.
Adequate clearance for air openings into the combustion chamber is required. Do not place objects between the bottom of the unit and
the counter top.
There must be adequate clearance for removal of the front panel. All major parts except the
burners are removable thru the front if the gas line is disconnected.
European Community Installation Instructions:
“THIS APPLIANCE MUST BE FITTED BY A COMPETENT PERSON. IN THE U.K., CORGI REGISTERED INSTALLERS (INCLUDING
THE REGIONS OF BRITISH GAS) UNDERTAKE TO WORK TO SAFE AND SATISFACTORY STANDARDS. THIS APPLIANCE
MUST BE INSTALLED IN ACCORDANCE WITH THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS AND THE RELE-
VANT BUILDING REGULATIONS / I.E.E. REGULATIONS. DETAILED RECOMMENDATIONS ARE CONTAINED IN THE FOLLOW-
ING BRITISH STANDARD CODES OF PRACTICE - BS 6172, BS 5440 PART 2, BS 6891”
“THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE RULES IN FORCE”
“MUST BE INSTALLED IN A WELL VENTILATED AREA. Ventilation requirements ie. B.S. 5440.”
NOTICE THE UNIT, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED AND COMPLY WITH LOCAL
CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL CODE ANSI/NFPA 70-
LATEST EDITION.
CANADIAN INSTALLATION MUST COMPLY WITH CSA-STANDARD C.22.2 No. 0 M1982 General Requirements -
Canadian Electrical Code, Part II, 109-M1981 - Commercial Cooking Appliances.
NOTICE Local codes regarding installation vary greatly from one area to another. The National Fire Protection Asso-
ciation, Inc. states in its NFPA 96 latest edition that local codes are "authority having jurisdiction" when it comes to
requirements for installation of equipment. Therefore, installations should comply with all Local codes.