Product manual
Model Width
in. (mm)
Depth
in. (mm)
Height
in. (mm)
No. of
Burners
BTU/kW Per Burner
Natural gas
Total
BTU / kW Hour
W.C.
in. (‘mbar’)
GCB-18H 18 (457) 25 (635) 15.5 (394) 1 60,000/17.5 60,000/17.5 6/10(15/25)
GCB-24H 24 (610) 25 (635) 15.5 (394) 2 40,000/11.7 80,000/23.5 6/10(15/25)
GCB-36H 36 (914) 25 (635) 15.5 (394) 2
60,000/17.5 120,000/35 6/10(15/25)
GCB-48H 48 (1220) 25 (635) 15.5 (394) 4 40,000/11.7 160,000/46.8 6/10(15/25)
GCRB-18H 18 (457) 25 (635) 15.5 (394) 1 60,000/17.5 60,000/17.5 6/10(15/25)
GCRB-24H 24 (610) 25 (635) 15.5 (394) 2 40,000/11.7 80,000/23.5 6/10(15/25)
GCRB-36H 36 (914) 25 (635) 15.5 (394) 2
60,000/17.5 120,000/35 6/10(15/25)
GCRB-48H 48 (1220) 25 (635) 15.5 (394) 4 40,000/11.7 160,000/46.8 6/10(15/25)
Specifications And Dimensions:
5
CONVERSION (Not Available in the European Community
Instructions are for conversion from Natural Gas to Propane (L.P.) on all models GCRB and GCB.
The conversion should b done before connecting the unit to the gas supply.
1. Remove the knobs and front panel.
2. Remove the supply tubes that go between the valves and the orifice fittings.
3. Remove the orifice fittings from the firebox. Change the orifices to the size recommended for propane (L.P.).
4. Replace the orifice fittings into the firebox.
5. Replace the supply tubes between the valves and the orifice fittings.
6. Replace the front panel, grease drawer and knobs.
7. Reverse plug in pressure regulator. The marking on the plug facing out should match gas supply.