Operating instructions
5
Warning! Operating environment
Ensure that operation location is at least 1” in all directions from combustible walls and materials
otherwise combustion or discoloration could occur.
Warning! Operating environment WGST
Ensure that the front and rear louvers are unobstructed with at least ½” space between it and other
surfaces.
Caution! Operating environment
Place unit on a stable, level floor. The unit must be level, both front and back and left to right, in
order to maintain an equal water depth throughout the wells. To eliminate rocking or adjust height
turn the adjustable feet in the proper direction until the desired results are obtained.
Note: Maximum adjustment is 1 inch
5. Before permanently connecting the gas line, the unit should be adjusted to the desired height and align
with other equipment.
6. The gas type and input rate ratings of this steam table are given on the device nameplate. Only connect
to that type of gas.
7. Connect unit to a supply line with a supply pressure at or above the required supply pressure (12.5”
max).
Warning! Using this unit without the regulator MAY cause personal injury and WILL void your
warranty.
8. The body of the appliance should be grounded by connecting to a good electrical ground, such as a
water pipe, a steam pipe, or a grounded supply conduit.
9. The steam table must be installed as required by local code authorities.
10. To assemble the units follow steps 1 thru 6 listed below.
11. The bottom adjustable shelf assembly shall be installed such that there is a minimum clearance of 6
inches between the shelf and the supporting surface.
12. After the bottom adjustable shelf assembly is installed, the Allen screws shall be capped with
the supplied plastic screw caps.
UNIT IS SHIPPED UNASSEMBLED. TO MEET NATIONAL SANITATION
FOUNDATION STANDARDS, THE INSTALLER MUST USE A NSF APPROVED
SILICONE SEALANT TO SEAL THE SEAMS BETWEEN THE
UNIT AND ASSEMBLED PARTS
Step 1
Insert the bullet leg into the 4 tubes.
When inserting bullet legs, use a soft mallet only. To avoid damaging the leg inserts.