Replacement Parts List
Key Part Number Description Quantity
1 31007-19 Pan well 1
2 820171-00 Bottom panel 1
3 20661-00 Pressure regulator (convertable) 1
4 20656-07 Pilot shutoff valve 1
5 20660-08 Manifold 1
6 20680-00 Burner valve 1
7 20688-62 Oriface spud #62 (natural gas) 1
8 20688-74 Oriface spud #74 (propane gas) 1
9 20658-15 Burner 1
10 820164-00 Burner support bracket 1
11 20661-53 Pilot 1
12 820168-01 Pilot bracket 1
13 820192-00 Pilot supply tubing 1
14 820183-00 Pilot shield 1
15 86321-00 Adjustable leg 4
16 87053-03 Knob 1
9
Conversion
For conversion from natural gas to propane (L.P.)
This conversion should be done before connecting the unit to the gas supply.
1. Remove the knobs and front panel.
2. Remove the supply tubes that go between the valves and the oriface fittings.
3. Remove the oriface fittings from the firebox. Change the orifaces to the size recommended for
propane (L.P.).
4. Replace the oriface fittings into the firebos.
5. Replace the supply tubes between the valves and the orifaces fittings.
6. With the unit on its back or side, reverse the plug in the pressure regulator. The marking on the
plug, facing out, should match the type of gas supply desired.
7. Replace the front panel and knobs.
8. Continue with the installation.
Note: Mainifold pressure should be checked after connecting to the gas supply. It should be
10 inches (24.5 cm) water column for propane (L.P.). Leak test all joints.
If you have any questions or problems, contact your nearest APW/Wyott