Table Top Game User Manual

NOTE: Before installing this product as part of a saline water purification system in a pool or spa using
natural stone for coping or for immediately adjacent patios/decking, a qualified stone installation specialist
should be consulted regarding the appropriate type, installation, sealant (if any) and maintenance of stone
used around a saline pool with electronic chlorine generator in your particular location and circumstances.
Installation Steps
Details on each installation step are presented on the following pages:
1. Prepare the pool water (page 3)
General Water Chemistry
Salt
2. Mounting the equipment (page 6)
Aqua Logic main unit
Remote display/keypad (optional)
Temperature sensors
Valve actuators (if applicable)
3. Plumbing (page 9)
General Pool Equipment
Turbo Cell
Flow Switch
4. Electrical Wiring (page 13)
Main service
Grounding and bonding
Circuit breakers
Aqua Logic control power
High Voltage pool equipment
Low voltage wiring (temperature sensors, flow switch, etc.)
5. Aqua Logic control configuration (program desired control operation) (page 22)
6. System Startup and checkout (page 36)
2
All Timeclocks
7-day
Move to previous/next configuration menu
Toggle between 7-day (default) and Weekend/Weekday time options
+
>
>
This selection affects ALL of the timeclock logic in the Aqua Logic. If “7-day” is selected,
each timeclock will have one set of turn-on/turn-off settings that operate every day of the
week. If “Weekend/Weekdays” option is selected then the user can enter one set of turn-on/
turn-off times for the weekend (fixed as Saturday/Sunday) and another set of turn-on/turn-
off times for weekdays (Monday through Friday).
Time Format
12 hour AM/PM
Units
ºF and PPM
Move to previous/next configuration menu
Move to previous/next configuration menu
Toggle between 12 hour AM/PM (default) and 24 hour time format options
Toggle between ºF and PPM (default) and ºC and g/L (Metric) options
+
+
>
>
>
>
Reset Config. to
Default Press +
Are you sure?
+ to proceed
Config. reset
Confirmed
Initiate reset of all configuration parameters
Reset all configuration parameters
Move to previous/next configuration
menu (config. not reset)
Move to previous/next menu (config. not reset)
Move to previous/next configuration menu
+
+
>
>
>
>
>
>
Use this function to erase all previous system configuration settings and reset all configura-
tion parameters back to the factory default values. This function is NOT reversible--be
careful.
6. System Startup and Checkout
Before Startup
Before starting the Aqua Logic for the first time, be sure that the following items have been completed:
1. Pool/spa chemicals are within the recommended levels according to the chart on page 3.
2. Pool/spa salt level is between 2700 – 3400 PPM.
3. Properly rated circuit breakers are installed in the Aqua Logic subpanel.
4. All wiring is performed according to NEC and local codes.
5. The Aqua Logic is properly grounded and bonded.
6. The Aqua Logic is properly configured to control all desired functions.
Program Automatic Operation
Refer to the programming flow chart on the back cover of this manual for a listing of the available menus
and the items included in each menu.
Settings Menu
Heater(s) and/or solar thermostat settings
Chlorinator settings
Day and Time
Timers Menu
Timeclock and/or Countdown timer settings
37