A ll Button and O neTouch™ C ontrol Panels
Important Safety Precautions When installing and using this electrical equipment, these basic safety precautions should always be followed: 1. READ AND FOLLOW ALL INSTRUCTIONS. LIRE LA NOTICE TECHNIQUE. 2. DANGER - to reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. 3. All electrical work must be performed by a licensed electrician and must conform to all national, state, and local codes. 4.
Table of Contents 2 Safety Precautions Safety Precautions Specifications Dimensions 3 Table of Contents 4 System Overview Controller Package Power Center Options and Accessories 5 Other Options Specialty Boards TeleLink Kit Surge Protection Kit 6-7 Basic Plumbing Standard Plumbing for Pool and Spa Non-Booster Pump Pressure-Side Pool Cleaner Plumbing Booster Pump Pool Cleaner Plumbing Solar System Plumbing 8-11 Power Center Connection Power Center Preparation High Voltage Wiring Low Voltage Wiring
System Overview *Not Available in CE Models 4
Other Options Sp ec ia lty Bo a rd s JVA R e la y In terloc k Bo a rd A ux ilia ry /JVA Re la y B o a rd Filter Pum p (N ormally Trans forme r S ocket Plug in JVA P3 P6 F I LT E R P U M P K 1 JV A 3 2 1 Re lay Co il J1 1 2 3 4 Trans forme r Connect ion JVA S oc ket K1 P4 Norm all y TB 1 J2 TB2 Norm ally O pen Extra R ela y Socket Plug into JVA R e la y A u x B o a rd is u se d to op e ra te a JV A 2 4 4 0 fro m a ny Au xilia ry D u a l S p a Sid e S w itc h Inte rfa c e B o a rd JVA
Basic Plumbing Non-Booster Pump Cleaner Plumbing Pool & Spa Plumbing Plumbing for Pool and Spa Combination. The diagram to the right shows a simplified version of a standard plumbing setup for a pool and spa that share the same filter pump, filter, and heater. The Intake and Return JVAs (Jandy Valve Actuators) turn simultaneously so when the Spa button is pressed on the AquaLink® RS Controller, water circulation switches between pool and spa.
Basic Plumbing Booster Pump Pool Cleaner Plumbing. Booster Pump Plumbing If you are using a Booster Pump Pool cleaner, plumb the booster pump so its suction side is connected to the pool return after the heater and as close to the ground as is practical (see diagram to the right). Please note that the installation of a booster pump pool cleaner requires moving DIP Switch #1 to the ON position. Solar System Plumbing.
Power Center Connection - High Voltage Mount Power Center. All electrical equipment, except for the Four Function Switch, must be five feet or more from pool /spa and comply with all national, state and local codes. If using a Jandy Power Center without built-in breaker compartment, install electrical supply panel with separate breakers for each load. Make sure that motors on equipment have built-in thermal protection. Use the grounding terminal, provided within the Power Center, for grounding.
Power Center Connection - High Voltage Power Center Connection - High Voltage 9 *This diagram shows wiring for a standard relay. For light dimming or two-speed operation, follow wiring instructions included with those relays.
Low Voltage Wiring (Power Center P.C. Board) Power Center Connection - Low Voltage If connecting more than 2 items to the RS Power Center red 4 pin terminal bar, a multiplex PCB is required.
Power Center Connection - Low Voltage 1. Connect 24V AC Power to Bezel and Mount Bezel. Plug the orange 24V AC power plug from the transformer into its 3-pin terminal on the back of the Low Voltage Bezel, feed battery wires to front right and connect the Bezel to the Power Center with the screws provided. DO NOT INSTALL BATTERY. 2. Mount JVAs & run wires to Power Center. Refer to the JVA manual to install JVAs.
Auxiliary Power Centers Auxiliary Power Center Installation You may have up to four (4) power centers on one (1) AquaLink RS system. The four conductor RS485 cable going to the 4-pin (red) terminal bar on the auxiliary power centers can be wired either from the main power center, the indoor control panel or an optional accessory. The auxiliary power centers can be located anywhere on the property, depending upon convenience and what devices are being controlled.
All Button Control Panel Installation Prepare Control Panel Site. With the aid of the homeowner, find the best location for the Control Panel. To ensure the Control Panel is level, hold the Mounting Bracket against the wall and mark the top inside of the upper right screw hole. Using this mark as a guide, place a level against the mounting wall and draw a horizontal line 4¼ inches to the left. Now use the Bracket as a template to mark holes for mounting screws (lining up the holes to the horizontal line).
Setup for Multiple Control Panels All Button Control Panel First Control Panel Third Control Panel Second Control Panel Fourth Control Panel Jumpers W2 W1 AquaLink RS Control Panel Jumper Setting: Move these jumpers only when installing more than one Control Panel on a system. The jumpers are used to give each Control Panel a unique system address. If you are using this Control Panel to replace an existing one, ensure the jumper settings match those on the one being replaced.
DIP Switch Settings Use a pen or small tip screwdriver to slide switch to the right to turn on. DIP #1 ON - —AUX 1 CONTROLS POOL CLEANER: If you installed a booster pump for a pool cleaner, the relay coil for the booster pump must be plugged into the AUX 1 relay socket. If a non-booster pump cleaner is installed, plug the JVA into the cleaner JVA socket. Turn on DIP Switch #1. • Main filter pump turns on whenever cleaner turns on.
OneTouch Control Panel Installation This document gives instructions for installing the Jandy ® AquaLink RS OneTouch Indoor Control Panel (surface and flush mount). The instructions must be followed exactly. Read through the instructions completely before starting the procedure. A . Installing the Flush Mount Control Box 1. 2. Upper Flange Determine the location of the controller. Be sure there is nothing behind the sheetrock where the controller will be mounted.
OneTouch Control Panel Installation Face Plate Face Plate PCB w/LCD & Buttons PCB w/LCD & Buttons Surface Mount Box Flush Mount Box Figure 5. AquaLink RS One Touch (surface and flush mount) Assembly 8. Place the PCB w/LCD and buttons back into the box. Be sure the rubber washer is between the screw head and the PCB. Hand tighten the screws. Snap the cover over the box. B . Installing the Surface Mount Control Box 1. Determine the location of the controller.
OneTouch Installation Templates Template 1- Flush Mount 4.03" WARNING Do not cut the sheetrock any bigger than the template. 4.03" Figure 7. Flush Mount Template Template 2- Surface Mount Drill Thru 3/16" (3) Places Drill Thru 1¼” Figure 8.
All Button Control Panel Programming and System Defaults Basic Programming. To set a particular piece of equipment to turn on and off at predetermined timeS, press the MENU button, scroll to the PROGRAM MENU, press ENTER, and then press the button for the equipment that you want to program. The Controller Display will ask you to enter the day. Use the arrow keys <—>* to select, and press ENTER. The display will now ask you for the starting time and ending time.
All Button Control Panel Reset and Display Messages Reviewing: To review equipment, press the MENU button, then use the FORWARD arrow to scroll to the REVIEW menu. Press ENTER, use the arrows to scroll to the item you wish to review, and press ENTER again. Canceling Items: If you make a mistake in programming or you want to change, for example, the ON/OFF times for a specific device, you can cancel programs for that piece of equipment.
OneTouch Control Panel Programming and System Defaults Basic Programming. To set a particular piece of equipment to turn on and off at predetermined times, highlight EQUIPMENT ON/OFF and press select. To highlight an item, use the up or down buttons. Use the SELECT button to turn the equipment on or off. After turning a piece of equipment on, return to the main menu by using the back button. Repeat this process for each piece of equipment that you wish to program.
OneTouch Control Panel Reset and Display Messages Resetting the System: To remove all labeling, programming, assignments, and temperature settings, highlight MENU/HELP press select, highlight SYSTEM SETUP press select, highlight CLEAR MEMORY and press select. Select CONTINUE, then select either yes or no to clear memory. There will be a 15 second delay before you see the FINISHED screen, select CONTINUE to return to SYSTEM SETUP.
Four Function Spa Side Remote Provisions The Four Function Spa Side Remote is a double insulated, submersible device which is ETL listed (to UL Standard 1563) for installation at the water’s edge. It is typically installed at the tile-line of the spa wall, or in the deck within arm’s reach of the spa. It can be used with a gunite spa, acrylic spa, or hot-tub.
SpaLink® RS Remote Provisions NOTE: For use with an AquaLink® RS System, ONLY! AquaLink RS software revision must be Rev. “G” or later. For Vertical Installation into the Spa Wall: Install a 6" piece of 1½” or 1" schedule 40 PVC pipe in the pool/spa wall so that the SpaLink RS Remote will not be constantly submerged. A 1½” to 1" adapter is included for use if 1½” PVC pipe is being used. This pipe will house the remote installed vertically in the wall of the pool or spa.
SpaLink® RS Remote Provisions For Horizontal Installation into the Deck: To house the SpaLink RS, plumb a 6" long piece of 1" schedule 40 PVC pipe. A 1½” to 1” adapter is included for use if 3¼" 1½” PVC is being used. Carefully trim the end of the pipe flush with the deck after all the deck work is completed. Leave at least 1" 2” of clearance around the conduit from coping stones or other raised objects.
AquaRite® Chlorine Generator Installation Installation Instructions: The Jandy AquaLink RS and AquaRite use a 4-wire connection to communicate and can be wired up to 500' apart. Any outdoor rated 4 conductor cable can be used. Locate appropriate screw terminals on the circuit board according to the diagram below (screw terminals are removable to aid in installation). IMPORTANT: attach wires to like numbered screw terminals on both the AquaRite® and AquaLink RS.
AquaLink® RS Troubleshooting Quick Check List Symptom Problem Possible Solution Power Center override switches operate when in Service or Time Out Mode, but the Controller is completely dead (no lights on, no display). Power supply problem. Check connection of the outside two wires (red and green) of the four conductor cable. If wired correctly, check the voltage between these two wires voltage should be 10 VDC.
® AquaLink RS Troubleshooting Quick Check List Symptom Problem Possible Solution Power outage with dead battery. At Controller, check battery level. With software level Rev. F or newer, battery status is located in Diagnostics section of System Setup Menu. One button on the Four Function Switch or SpaLink RS does not operate. Check programming first. If the Four Function Switch or SpaLink RS is programmed correctly, the button may be shorted. Replace the Four Function Remote or SpaLink RS.
AquaLink® RS Natural Gas Heater Connection Installation Guidelines (also includes propane heaters) General Heater Wiring Guidelines: Electric Heaters and Heat Pumps This instruction sheet is for low voltage heaters. Do not attempt to connect a heater with a high voltage (110 or 220 VAC) thermostat into the low voltage heater terminal bar. MAX 3 ON 4 Natural Gas Heaters and Propane Heaters 1.
AquaLink®šš RS Heater Connection Installation Guidelines (Continued) Typical RayPak Heater Connection Guidelines for RayPak Heaters: Heater Wiring with AquaLink RS For RP2100: (Models: P-R185A to P-R405A, C-R185A to C-R405A, P-R185AL to P-R405AL, C-R185AL to C-R405AL, from Catalog #6000.52-X) 1. For the 2-wire/1 function configuration, connect the orange/ black and black/orange wires to one contact and the yelow/ black wire to the other contact.
All Button Control Panel Cancel Flow Chart CANCEL SOME PROGRAMS Select Device To Be Canceled CANCEL ALL FRZ PROTECT Press ENTER to Remove All Devices Except Pump from Freeze Protection or Cancel to Abort AUX LABEL Select AUX to Remove Label From Label Removed DIMMERS Press ENTER to Cancel Dimmers or Cancel to Abort Select AUX to Remove Dimmer From CLEANER JVA No JVAs Assigned to AUXs JVA ASSIGN SOLAR JVA SYSTEM SPA SWITCH LOCKOUTS SPA LINK DEVICE 31 UNLOCKED
All Button Control Panel Menu Flow Chart On All Days PROGRAMS PROGRAM Select Equipment On Weekends TEMP SET On Weekdays SPA SWITCH On Specific Day REVIEW SPA LINK FRZ PROTECT POOL TEMP AUX LABELS SET TEMP SPA TEMP DIMMERS SET TIME Set Year, Day, Hour & Minute SYSTEM JVA ASSIGNS LOCKOUTS SPA SWITCH LOCKOUTS SPA LINK DEVICE PGM GROUP GROUP A GROUP B ON Select Equipment Main Label Menu DISPLAY LIGHT OFF LABEL AUX SPA SWITCH 1 SWITCH 2 SWITCHES Assign Buttons 3 SWITCHES 1 SPA LINK SPA LINK
OneTouch Control Panel Menu Flow Chart O N ETO UC H 1 O N ETO UC H O N/O FF E Q UIPM E NT O N/O FF ON O N ETO UC H 2 O N ETO UC H 3 S elect E quipme nt O FF ON O FF K EY S S ERV ICE D IA G NO ST IC S G O BA CK H ELP S elect E quipme nt P RO G RA M A DD PR O G RA M P O O L H E AT S ET TE MP S ET TIM E N EX T S PA H EAT S et mont h, d ay, yea r, and time ON D IS PLAY LIG H T O FF 2 M IN .
O p t io n a l S e t ON C le a n e r 2 spd pum p S p a S p illo v e r D is a b l e d S ee M anual S p a re A u x S p a N ot U sed H eat Pum p N ot U sed N ot U sed R ed B lack W a t e r Te m p . R ed B lack Senso r S o la r S ensor L o w V o lta g e H e a te r R ed B lack G re e n W h it e B ro w n B lue 6 5 4 3 2 1 A ux. 1 A ux. 2 J V A S o ck e ts (2 4 V A C o u tp u t) To S e ns ors , e tc . (g ree n t e rm . b a r) R e la y S o c k e ts (2 4 V D C o u tp u t) F.
Notes 35
C US Listed 4J39 Swimming Pools & Spa Controllers 6000 Condor Dr., Moorpark, CA, USA, 93021 • 707.776.8200 FAX 707.763.7785 480 S. Service Road West, Oakville, Ontario, Canada L6K 2H4 • 905.844.8233 FAX 905.844.2635 Litho in USA © Water Pik Technologies, Inc. Sheet #6594, Rev E, 9/01 For Technical Support call 707-776-8200, ext.