Specifications
12
Auxiliary Power Centers
Auxiliary Power Center Installation
You may have up to four (4) power centers on one (1) AquaLink RS system.
The four conductor RS485 cable going to the 4-pin (red) terminal bar on the auxiliary power centers can be wired either from
the main power center, the indoor control panel or an optional accessory.
The auxiliary power centers can be located anywhere on the property, depending upon convenience and what devices are
being controlled.
AUX B1 through B8, C1 through C8, and D1 through D8 on the indoor control panel operates the relays located in the
auxiliary power centers. AUX B1 through B4 JVA sockets are energized when AUX B1 through B4 relay sockets are
energized.
Note: If you are installing more than one accessory board, order and use a Jandy Multiplex Kit (p/n 6584). Never put more
than two wires into each of the pins of the terminal bar. Use the multiplex board whenever more than two of the 4-wire cabes
are being joined.