Specifications

14
AquaLink RS Control Panel Jumper Setting: Move these jumpers
only when installing more than one Control Panel on a system.
The jumpers are used to give each Control Panel a unique
system address. If you are using this Control Panel to replace an
existing one, ensure the jumper settings match those on the one
being replaced.
The AquaLink RS allows each system to support a maximum of four Indoor Control Panels. The Control Panels
may be wired "In Series", starting from the first Control Panel (solid line), or each may be wired individually from
the AquaLink Power Center (dotted line), or a combination of the two. To accomplish the "In Series" wiring
scheme, you may "double-up" wires in the red terminal bars, but never put more than two wires into each pin of
the terminal bars. If you need to join more than two of the 4-wire cables, order and install Jandy Part # 6584
(Multiplex PCB Kit).
OR
OR
OR
All
Button
Control
Panel
First Control Panel
Third Control Panel
Second Control Panel Fourth Control Panel
W2
W1
Micro
Processor
Red 4 pin
connector
Jumpers
OneTouch
Control
Panel
Setup for Multiple Control Panels
TM
TM
TM