Specifications
15
DIP Switch Settings
DIP #1 ON
- -
- -
- —
AUX 1 CONTROLS POOL CLEANER:
If you installed a booster pump for a pool cleaner, the relay coil for the booster pump must be plugged into the AUX 1 relay
socket. If a non-booster pump cleaner is installed, plug the JVA into the cleaner JVA socket. Turn on DIP Switch #1.
• Main filter pump turns on whenever cleaner turns on.
• Cleaner will not turn on until filter pump has been on for 3 minutes (to ensure priming of system).
• Cleaner turns off when water circulation is to spa.
• Cleaner turns off when spa overflow feature is activated.
• Cleaner turns off for 3 minutes when solar is activated (to ensure air is purged from system).
• AquaLink RS Controller Display reads “CLEANER” rather than “AUX 1”.
DIP #2 ON
- -
- -
- —
AUX 2 CONTROLS LOW SPEED OF FILTER PUMP:
Turn this switch on if you want to control both speeds of a two-speed filter pump. With this switch on, the filter pump button
on the AquaLink RS Controller will control high speed and the AUX 2 button will control low speed. IMPORTANT: You must
also install a Jandy Two-Speed Relay, purchased separately. Install the Relay according to its installation instructions.
DIP #3 ON
--
--
- —
AUX 3 CONTROLS SPA SPILLOVER (OPERATES WITH POOL/SPA COMBINATION UNITS):
Turn this switch on, and when the AUX 3 button on the AquaLink RS Controller (or Spa Side Switch) is pressed, the Return
Valve Actuator will rotate to spa circulation. Because the Intake Valve Actuator does not rotate, the spa will fill with water
and overflow into the pool. NOTE: Leave AUX 3 relay socket empty.
DIP #4 ON -
HEATER COOL DOWN DISABLED:
Turn this switch on to disable the heater cool down safety feature on the AquaLink RS. WARNING: Turn this DIP Switch on
only if you are using an electric heater or heat pump that does not retain residual heat. If you are turning this switch on for
service purposes, be sure to turn it back off after you have finished.
DIP #5 OFF - FACTORY USE ONLY:
This switch is used for calibration by Jandy technicians only, and to momentarily display the solar temperature.
Please leave this switch in the
off position.
DIP # 6 ON - Change Spare AUX. to active when Filter Pump is on and system is in spa mode (pool/spa combination
units only).
DIP #7 - —
NOT USED.
DIP #8 ON -
HEAT PUMP INSTEAD OF GAS HEATER:
Turn this switch on if you have installed a heat pump instead of a gas heater.
Use a pen or small tip screwdriver to slide switch
to the right to turn on.