OneTouch Control Panel Installation
This document gives instructions for installing the Jandy
AquaLink
®
RS OneTouch Indoor Control Panel (surface
and flush mount). The instructions must be followed
exactly. Read through the instructions completely before
starting the procedure.
A.A.
A.A.
A.
Installing the Flush MountInstalling the Flush Mount
Installing the Flush MountInstalling the Flush Mount
Installing the Flush Mount
Control BoxControl Box
Control BoxControl Box
Control Box
1. Determine the location of the controller. Be sure there is
nothing behind the sheetrock where the controller will be
mounted.
2. Place Template 1 in the location chosen for the control
panel, cut a square in the sheetrock. Be careful to cut
accurately with a razor knife or equivalent. Do not make
the square oversized.
3. Run the 4 conductor wire, and pull it through the hole in the
wall.
5 Pull the 4 conductor wire through the large hole in the flush
mount box. Then push the box into the wall.
6. Depending on what size sheet rock (5/8" or 1/2") determine
which side of the cleat to be used.
a. For 1/2" sheet rock face the large side of the cleat
towards you (see Fig. 2).
b. For 5/8" sheet rock, face the small side of the cleat
towards you (see Fig. 2).
7. Insert a screw through the screw boss. Put a cleat into the
top U shaped hole (with the orientation determined in
Step 4). Thread the screw into the cleat. Hand tighten with
a Phillips screwdriver. Repeat with second screw and
cleat using the bottom hole. (see Fig. 3 & 4).
Slide cleat
into slot
opening,
thread screw
into cleat.
Lower flanges of
cleat prevent the
part from falling
through the
flush mount box.
Upper flanges of
cleat provide a
snap fit with top
wall of box.
This allows the
screw to be
inserted without
having to hold
the cleat
Figure 4. Cleat Location
This Side and
Tip for 5/8"
Sheetrock
Upper Flange
This Side and
Tip for 1/2"
Sheetrock
Lower Flange
Figure 2. Cleat Orientation
Slot Openings
Through Top,
Bottom, and
Back Walls
Screw
Bosses
Figure 3. Cleat Location
Flush
Mount
Box
Sheetrock
(1/2" or 5/8"),
with 4" Square
Cut Out
Outside Wall Surface
Figure 1. Flush Mount Box Positioned in Sheetrock