INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series
Congratulations on your purchase of this Aqua-Pure® high flow, single housing filtration system. This system is ideal for large homes, restaurants, schools, clubs, farms, camps, and institutions of all types. This system is ideal for locations where flow rates range up to 288 gallons per minute (1,090 lpm). The all-metal housing is available with AP110, AP117, AP017 or without cartridges and features a single clamp for easy cover removal.
HOUSING WALL IN VALVE OUT VALVE DRAINS 2 VALVES (EACH DRAIN REQUIRES A VALVE) MAIN DRAIN WALL HOUSING IN VALVE OUT VALVE DRAIN DRAIN FAUCETS Figure 1 3
SS4-316L, SS8-316L, SS12-316L and SS20-316L Filter Housing Series Installation 1)Installing the Filter Housing (SS4-316L, SS8-316L, SS12-316L and SS20-316L Filter Housing Series) The filter housing should be placed on 8” (20 cm) cinder or cement blocks to permit ease of draining. Locate the inlet (marked as “IN” and Outlet (marked as “OUT”) connections on the housing cylinder.
2)Installing the Filter Cartridges Remove the v-band clamp (item 6). Remove the top cover (item 3). Remove the top cover gasket (item 5) and place on a clean flat surface or hang on a hook. Remove the hand knob (item 2) and lift off the pressure plate (item 4). This will expose the cartridge posts (item 7). Insert the cartridge posts into the cartridge pedestals (item 10) making sure the posts are vertical within the housing.
SS24-316L, SS36-316L Filter Housing Series 1)Installing the Filter Housing (SS24-316L and SS36-316L Filter Housing Series) Locate the Inlet (marked as “IN” on the flange) and Outlet (marked as “out” on the flange) connections on the housing cylinder. Connect the water supply line piping to the Inlet connection and the filtered water piping serving the building to the Outlet connection. Shut off valves are to be installed on each side of the housing (see Note).
2)Installing the Filter Cartridges Remove the v-band clamp (item 9). Remove the top cover (item 6). Remove the top cover gasket (item 8) and place on a clean flat surface or hang on a hook. Remove the lock nut (item 2) and lift off the pressure plate (item 7). This will expose the spring and seal plate assemblies (item 10) and cartridge posts (item 11). Carefully pull the spring and seal plate assemblies off the cartridge posts.
CARTRIDGE INCLUDED SS4 EPE - 316L SS8 EPE - 316L SS12 EPE - 316L SS20 EPE - 316L SS24 EPE - 316L SS36 EPE - 316L 55278-13 55278-14 55278-15 55007-03 55008-10 55008-11 X X X X X X SS MATERIAL X X X X X X X X X X X X SS4 EPE-316L Series SS8 EPE-316L Series SS12 EPE-316L Series IN OUT SS20 EPE-316L Series SS24 EPE-316L Series SS36 EPE-316L Series Suffix Length N/A 9 3/4" -2 19 1/2" -3 29 1/4" -4 39" Suffix Length N/A 10" -2C 20" -3C 30" -4C 40" Visit www.nsf.