Owner`s manual

5
5. Every supply should be copper to ensure proper connection. Do not use aluminum supply.
6. The electrical installation must contain a switch or a differential circuit breaker 30mA differential
capable of protecting property and persons in case of leakage current to earth.
7. The circuit for the spa must include adequate protection vis-à-vis consumption for Electric spa.
Refer to Section 5.0 Power required for your spa model.
8. To access the connector block of the spa, remove the screws from being under the keyboard and
remove the panel. Remove the screws from the cabinet to open gain access.
9. Choose a suitable access place for your cable (eg a corner) and run the cable into the tub along the
skins to the connection box.
10. Bring the cable through the gland, in front of the connector and insert the cables in the connector
according to the following:
Live. (Red or Brown)
Neutral. (Blue)
Earth. (Green & Yellow)
11. Once the connections are made, close the connection box.
5.0 Power requirements
Provence
Cable thickness 4m
Protection 25A
The values section of cable is purely indicative for a distance between the General Electric and the
spa of less than 20m. If this distance is greater, it will require a higher specification cable. If you are
unsure, ask the advice of a licensed electrician.
WARNING: In the configuration defined by the plant, the heater will automatically cut off when
the massage pumps are functionning, to limit the amperage. However, you can change this
setting and allow the heater working together with the pumps. In this case, it is imperative to
review the values of sections of cable and electrical protection. Ask your dealer to define these
values.
6.0 Procedure for filling the spa
FOR BEST RESULTS, READ EACH STEP COMPLETELY BEFORE YOU START THE PROCESS.