Owner`s manual

OPERATINGINSTRUCT IONS
Tooperateyourspayouuseyourmaincontrolpanel(keypad). itfeatures 4
buttons(Pump,Blower,Light,Up/Down)andanLCDscreen,whichdisplays
informationonthestatusof thesystem,suchasthewatertemperatureorerror
messages.
KeypadTSC9
Keyto DisplayPanelIconsandButtons
Button /icon Blinking On
Pump active
Bloweractive
displayshowsdesired
temperature
Heaternot active,but wat eris
heatedtodesiredtemperature.
Heateractive
Lighton(highintensity)
Filterfunctionsuspended Filterfunctionactive
AquaSpa Owner´sManual, page11
MAINFUNCTIONS
Thissectiondescribesthemostcommonlyusedfunctionsduringtheoperationofthe
contr oller.
Typically,eachfunctionismanagedbyaspecificbutton,howeversometimesthesame
buttoncanbeusedtocontrolmorethanonefunction(dependingon theversionofthe
firmwareinstalled).
Thetablebelowsummarisesthefunctionsassignedtoeachbutton.
Button Function
Pump
Startsand stops jetpump.
Blower
Starts andstops theblower.
Light
Switchesthelightonandoff
Up
Increasethevalues beingset.
Down
Decreasethevaluesbeingset.
Pump ifthepumpisnotstoppedmanually,itstopsautomaticallyafter20minutesof
continuousoperation.
Light ifthelightisnotswitchedoffmanually,itswitchesoffautomaticallyafter20
minutes.
Blower iftheblowerisnotstoppedmanually,itstopsautomaticallyafter20 minutesof
continuousoperation.
Filtration duringoperation,thefiltericonisonsteady;ifoneofthebuttons,pump,
blowerorlightispressedduringapurgecycle,thecycleisinterruptedandwillonly
resume40minutesafterthelastdevicestops.
Filteringfunction. Whenthefiltrationcycleisactive,thefiltericonwilllightup
continuosly.The spaisprogrammedtorunafiltrationcycleonceaday for6hours.
Duringthefiltrationcyclethe pump andblowerrun inhighspeed modeforoneminute
topurge theplumbing,followedbythe pumpatlowspeedfortherest ofthecycle.Itis
possible toprogramthedurationofthefiltrationcycle.Holdthe“light”buttonfor5
seconds,thedisplayshowsthecurrentdurationvalue.Usethe“Up/Down”keytoadjust
thisvalue.Pressagainthe“Light”key,thedisplayshowstheparameterDindicatesthe
numberofhourstodelaythestartofthefiltrationcycle,use the“Up/Down”keyto
adjustthevalue.
Duringthe setup,iftheuserdoesntpress anykeyfor5seconds,thesystemmemorises
thenewsetting,butitwilltakeeffectonlyatthenextcycle.However,iftheuserexitsthe
settingbypr essingthe“light key againthenewsettingismemorised.
Ifduringthefiltercycletheuserpresses anykey,thecycleissuspendedwhilstthespais
beingused.Oncethespahasbeeninactivefor40minutes thefiltrationcyclecontinues.
WhentheFiltrationcycleissuspendedthefiltericonLEDwillflashintermittently.
AquaSpaOwner´sManual, page12