Instructions / Assembly

Page 1 of 2 Rev B
Instruction Sheet for Water Lubricated Effective 12/19/16
Pumps with Replaceable Cartridge Supersedes 9/1/13
3 Speed Models IS-AM08-072
---------------------------------------------------------------------------------------------------------------------------------------------------------------
WARNING: When installing pump observe all applicable electrical and plumbing codes.
WARNING: To avoid electrical shock, disconnect power prior to connecting or disconnecting pump.
WARNING: Risk of electric shock. This pump has not been investigated for use in swimming pool or marine areas.
WARNING: This pump is acceptable for indoor use only. Employer uniquement à l’interieur.
CAUTION: This pump has been evaluated for use with water only. The suitability of this pump for use with liquids
other than water is the responsibility of the end-user.
CAUTION: When making electric connections, do not apply excessive external loads to junction box.
APPLICATION
1. AquaMotion circulators are designed to handle water and mixtures of water and up to
50% ethylene or propylene glycol. Not suitable for silicone based additives. The addition of certain chemical additives or
petroleum based products voids the warranty.
2. For closed loop systems, circulator with cast iron pump housings may be used.
3. For open loops and fresh or potable water, use pumps with stainless steel housings only.
4. Operating pressures may not exceed 125psi.
5. Maximum fluid temperatures must not exceed nameplate rating.
6. Maximum ambient air temperature is 104°F. ((For higher ambient temperatures consult factory).
INSTALLATION AND START- UP
1. Prior to installation, check circulator for damage due to mishandling.
2. Mounting position: The circulator may be installed with the motor in the horizontal position or vertically with the motor up. (Do not
install with the motor down).
3. Flow directions: An arrow on the pump housing indicates the direction of flow.
4. Rotating motor: The motor can be rotated relative to the pump housing so that the junction box is located in the most convenient
position. However, it must not be located at 6 o’clock when the motor is horizontal. To rotate the motor, remove the four housing
bolts, rotate and replace bolts. Make sure the 0’ring gasket is properly located in the recess of the pump housing.
5. Electrical connections: OBSERVE ALL APPLICABLE CODES WHEN CONNECTING POWER. Check nameplate for voltage
and ampere draw. The motor is impedance protected; no additional overload protection is required. The black supply wire may
be connected to either motor wire. The pump cannot run backwards. Use supply wires rated not less than 90°C. Use copper
conductors only. Attention: Employer des fils d’alimentation pour 90° C. Utilisez des conducteurs en cuivre seulement.
6. Charging the system: The bearings of the AquaMotion pumps are lubricated by the fluid being pumped, hence they never need
to be lubricated. However, to assure adequate initial lubrication, the system must be filled and pressurized. In vertical position, a
minimum of 20psi is required. DO NOT OPERATE THE PUMP UNTIL SYSTEM IS PROPERLY FILLED AND PRESSURIZED
7. When system has been properly filled, operate the pump for 5 to 10 minutes to further purge air from pump.
8. Adjust switch position by rotating knob to correspond with desired pump output. See curves on page 2.
Mounting Positions
**
** When the
For Indoor Use Only
circulator is
mounted in
this position
the system
pressure must
be 12 psi or
more.
ELECTRICAL DATA
SPEED
AMPERE
All Models AM10
All Models AMR
LO
.45
.46
MED
.60
.62
HI
.75
.79
REPLACING MOTOR ASSEMBLY
1. Disconnect power.
2. Reduce system pressure to zero and let fluid cool down.
3. Close shut off valves. If there are no shut off valves, drain system.
4. Remove pump housing bolts and pull out motor assembly.
5. Install new motor assembly using new 0-ring gasket. Make sure gasket is properly placed.
6. Follow installation procedure to start up circulator.