Use this section to check for the possible cause of simple troubles you may have with
your powerboard. You may solve some of the problems rather quickly, but may need help
from a skilled mechanical technician. In such cases, refer to an authorized Aquanami Dealer
for servicing. If a procedure for replacement or repair is not described in the Manual, have
an Authorized Aquanami Dealer perform necessary service.
TROUBLE POSSIBLE CAUSE REMEDY
Engine does not turn
over
Lanyard is not in place put Lanyard on post
battery runs down, bad terminal
connection
charge battery and tighten
terminal
fault start motor refer to a Aquanami dealer
bad electric connectors of start motor
cables
refer to a Aquanami dealer
seized jet pump refer to a Aquanami dealer
seized engine refer to a Aquanami dealer
faulty stop button, Lanyard post refer to a Aquanami dealer
bad start switch refer to a Aquanami dealer
bad relay switch refer to a Aquanami dealer
Engine turns slowly,
but does not start
weaken or discharged battery replace battery
bad battery cable connection tighten
worn start motor refer to a Aquanami dealer
Engine turns
regularly, but does
not start
empty fuel fill
stale or contaminated fuel tank clean and refill
watered/contaminated carburetor
drain carburetor, and drain
fuel water separator bottle
fouled or defective spark plug replace
spark plug cap not connected or loose tighten
fuel flooded engine refer to a Aquanami dealer
water flooded engine refer to a Aquanami dealer
disconnected or faulty fuel pump refer to a Aquanami dealer
defective electronic control box refer to a Aquanami dealer
Bad electric connectors
Clean and dry the
connectors
Trouble Shooting