9.2 Data table
Model AQC 3-1 AQC 3-2 AQC 4-2 AQC 4-3 AQC 5-2 AQC 6-2 AQC 8-2 AQC 9-3 AQC 10-2
612437 612438 612439 612452 612440 612441 612442 612453 612443
Voltage V 120 208 240 208 240 277 208 240 208 240 208 240 277 208 240
Phase 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Wattage kW 3.0 2.5 3.3 2.9 3.8 4.5 3.6 4.8 4.5 6.0 5.4 7. 2 9.0 7.2 9.6
Amperage A 25 12 14 14 16 17 18 20 22 25 26 30 32.5 35 40
Min. recommended circuit breaker
size
1
A
25
15
15
15
20
20
20
20
25
25
30
30
35
35
40
Min. recommended wire
size (copper)
2
AWG
10
14
14
14
12
12
12
12
10
10
10
10
8
8
8
Min. water flow to activate unit GPM / l/min 0.32 / 1.2 0.32 / 1.2 0.42 / 1.6 0.42 / 1.6 0.42 / 1.6 0.48 / 1.8 0.69 / 2.6 0.79 / 3.0 0.79 / 3.0
Pressure loss in unit PSI / bar 2.88 / 0.23 2.88 / 0.23 2.88 / 0.23 2.88 / 0.23 2.88 / 0.23 2.88 / 0.23 3.13 / 0.25 3.75 / 0.30 3.75 / 0.30
Nominal water volume GAL / l 0.13 / 0.5 0.13 / 0.5 0.13 / 0.5 0.13 / 0.5 0.13 / 0.5 0.13 / 0.5 0.13 / 0.5 0.13 / 0.5 0.13 / 0.5
Working pressure max. PSI / bar 150 / 10 150 / 10 150 / 10 150 / 10 150 / 10 150 / 10 150 / 10 150 / 10 150 / 10
Tested to pressure PSI / bar 300 / 20 300 / 20 300 / 20 300 / 20 300 / 20 300 / 20 300 / 20 300 / 20 300 / 20
Weight lbs. / kg 4.6 / 2.1 4.6 / 2.1 4.6 / 2.1 4.6 / 2.1 4.6 / 2.1 5.3 / 2.4 5.3 / 2.4 5.3 / 2.4 5.3 / 2.4
Water connections
3
" NPT 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2
AQC 3-1, 3-2, 4-2 ship with a 0.5 gpm (1.9 l/min) pressure compensating ow reducer/aerator that must be installed.
1
This is our recommendation for overcurrent protection sized at 100% of load. (dp for 240/208/277 v & sp for 120 v models). Check local codes for compliance if
necessary. Tankless water heater are considered a non-continuous load.
2
Copper must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load
3
For use with cold water supply only
10. Temperature increase above ambient water temperature
[ °F ]
Type kW GPM (gallon per minute)
0.32 0.42 0.48 0.5 0.69 0.75 0.79 1.0 1.5 2.0
AQC 3-1 3.0 65 49 43 41 30 27 26 20 14 10
AQC 3-2
2.5 54 40 35 34 25 23 21 17 11 9
3.3 71 53 47 45 33 30 28 22 15 11
AQC 4-2
2.9 47 41 40 29 26 25 20 13 10
3.8 61 54 52 38 35 33 26 17 13
AQC 4-3 4.5 73 64 61 45 41 39 31 20 15
AQC 5-2
3.6 58 51 49 36 33 31 25 16 12
4.8 77 68 65 48 44 41 33 22 16
AQC 6-2
4.5 64 61 45 41 39 31 20 15
6.0 85 82 60 55 52 41 27 20
AQC 8-2
5.4 54 49 46 37 25 18
7.2 71 65 62 49 33 25
AQC 9-3 9.0 - - - - - - 77 58 41 31
AQC 10-2
7.2 - 62 49 33 25
9.6 - 82 65 44 33
Min. water ow to activate unit
[ °C ]
Type
kW l/min
1.2 1.6 1.8 2.0 2.6 3.0 4.0 5.0 7.5
AQC 3-1
3.0 36 27 24 22 17 14 11 9 6
AQC 3-2
2.5 30 22 20 18 14 12 9 7 5
3.3 39 30 26 24 18 16 12 9 6
AQC 4-2
2.9 26 23 21 16 14 10 8 6
3.8 34 30 27 21 18 14 11 7
AQC 4-3
4.5 40 36 32 25 22 16 13 9
AQC 5-2
3.6 32 29 26 20 17 13 10 7
4.8 43 38 34 26 23 17 14 9
AQC 6-2
4.5 36 32 25 22 16 13 9
6.0 48 43 33 29 22 17 11
AQC 8-2
5.4 30 26 19 15 10
7.2 40 34 26 21 14
AQC 9-3 9.0 - - - - - 43 32 26 17
AQC 10-2
7.2 34 26 21 14
9.6 46 34 28 18