Specification

17 West Street | West Hatfield, MA 01088 | Toll Free 800.582.2213 | Phone 413.247.3380 | Fax 413.247.3369 | info@aptankless.com | www.aptankless.com
*AQM 2-1 is internally restricted to 0.32 GPM.
AQM 2-1, 2.5-1, 3-1 ship with a 0.5 GPM pressure compensating ow reducer/aerator that must be installed.
AQM 3.5-1, 4-2 ship with a 0.66 GPM pressure compensating ow reducer/aerator that must be installed.
AQM 6-2 ships with a 1.0 GPM pressure compensating ow reducer/aerator that must be installed.
AQM MODEL
Ultra-Low
Standard
Standard
Flow Rate at Sink
0.32
0.50
0.66
High 1.0
Flow
GPM
FL
Recommendations for 240 V units are correct if installed with 240 V service.
Increase one model size if unit will be installed with 208 V service.
Call Aqua Power® at 800.582.2213 if you have any sizing questions, or another out-of-the-ordinary
situation. Aqua Power® service representatives can make recommendations on sizing, or provide
assistance with our water heaters, to both homeowners and professional installers.
AQM Sizing Guide
Single Hand Washing Sink Tankless Electric Water Heater
Cool (Northern) Climate
Inlet water
45°F - 55°F
Cool (Northern) Climate
Inlet water
45°F - 55°F
Warm (Southern) Climate
Inlet water
55°F - 70°F
HI
AK
MB
ON
QC
PE
NS
NH
VT
MA
CT
RI
NJ
DE
MD
NB
ME
NY
PA
WV
VA
NC
KY
TN
SC
GA
MS
AL
MO
AR
LA
TX
FL
OH
IN
IL
ID
OR
WA
NV
MT
WY
UT
AZ
CA
NM
CO
IA
MN
ND
SD
NE
KS
OK
MI
WI
AB
SK
BC
AQM 2-1*
120 V
Requires 20 A
circuit breaker
AQM 3-1
120 V
Requires 30 A
circuit breaker
AQM 4-2
240 V
Requires 20 A
circuit breaker
AQM 6-2
240 V
Requires 30 A
circuit breaker
AQM 2-1
Designed for an ultra-low-
flow (.32 gpm) lavatory sink,
providing warm water for hand
washing at about 90100°F (32-
38°C)
Heats water 40°F maximum
An AQM 2-1 could supply, for
example, 0.32
gpm of warm
water at 90°F for hand washing
if incoming cold water was 50°F
AQM 3-1
Designed for a standard low-
flow (.5 gpm) lavatory sink,
providing warm water for hand
washing at about 90100°F (32-
38°C)
Heats water 40°F maximum
An AQM 3-1 could supply, for
example, 0.5
gpm of warm water
at 90°F for hand washing if
incoming cold water was 50°F
AQM 4-2
Designed for a standard-
flow (.66 gpm) lavatory sink,
providing warm water for hand
washing at about 90100°F (32-
38°C)
Heats water 39°F at a flow rate
of 0.66 GPM
An AQM 4-2 could supply, for
example, 0.66
gpm of warm
water at 89°F for hand washing
if incoming cold water was 50°F
AQM 6-2
Designed for a high-flow (1
gpm) lavatory sink, providing
warm water for hand washing
at about 90100°F (32-38°C)
Heats water 40°F at a flow rate
of 1.0 GPM
An AQM 6-1 could supply, for
example, 1.0
gpm of warm water
at 90°F for hand washing if
incoming cold water was 50°F
See next page for Technical Data & Temperature Rise curves.

Summary of content (2 pages)